Obstruction Sensitivity Potentiometer Setting
ALWAYS KEEP SAFETY AT THE TOP OF YOUR LIST WHEN ADJUSTING OR
SERVICING YOUR AUTOMATIC GATE OPERATOR!
IMPORTANT: For safety reasons the obstruction setting or
Stall Force on the GTO/PRO SW 1500 control board comes from
the factory set at MIN (minimum). In many gate installations
this setting will need to be adjusted to overcome the weight
and size of the gates.
The Stall Force potentiometer on the control board oper-
ates like a volume control on a radio. It controls the ob-
struction sensitivity (or the amount of force the operator will
apply to an obstruction) before it automatically stops and
reverses direction for approximately two (2) seconds.
Use a small slotted screwdriver to turn the arrow in the
center of the potentiometer. Adjust the sensitivity from the
MINIMUM position so the gate operates without obstructing
from its own weight or the wind conditions in your area.
NOTE: You may need to increase the
stall force in cold weather due to increased
resistance from gate hinges.
1
ON
2 3 4
15
CHARGING
POWER
STATUS
RF
PULL-PUSH
MODE
1
MODE2
LOCK/BEACON
OFF 120
MIN MAX
STALL FORCE
CLOSE TIME
SET
LIMIT
LEARN
REMOT
E
AUX OUT
SOLAR
PANEL
18VAC
REVR
GRN
BLK
RED
EXIT
SAFETY
EDGE
CYCL
E
COMMON
LINK
OFF 120
CLOSE TIME
Setting Auto-Close Time
CLOSE TIME (auto close timer): Determines how long
the gate will remain open before it automatically closes.
The limits are OFF to 120 seconds. The factory setting is
MIDWAY.
NOTE: Auto Close only works when the gate is in the fully
open position. If the gate is stopped before it reaches the
fully opened position it will have to be activated again with
an input device like a transmitter, push button or keypad.