User Guide
6
SHIELD from WAND Cable
BLACK wire from Range
Adjustment control board
RED wire from WAND Cable
BLACK Operator Battery Wire
BLACK BATTERY CONNECTION Wire
with Spade Connector included with WAND
RED BATTERY CONNECTION Wire
with Spade Connector included with WAND
Double Spade Connectors
included with WAND
RED Operator Battery Wire
Adjusting the Range:
Step 16: Test the WAND to see if it is working properly and if the
RANGE needs adjusting for optimum performance.
• Turn the potentiometer (POT) clockwise to increase range.
• Turn the potentiometer (POT) counter-clockwise to decrease range.
Replace the control box cover and bury the WAND and wire.
MIN MAX
Safety Precautions:
Step 17: Place the WARNING SIGNS on both
sides of the gate using tywraps included.
!
WARNING
GA
TE OPENING
SENSOR IN USE
The Automatic Gate Opener is activated when a
vehicle comes within range of the sensor buried
along side the driveway and could possibly be
activated by a child on a bicycle, tricycle or other
metal play equipment.
8.5"
4.38"
REWWARN01
Powering Up the WAND:
IMPORTANT: When the WAND is
first powered up it must be undis-
turbed for 60 seconds to perform
the self test and calibrations. Before
powering the WAND make sure
there are no moving metal objects or
moving vehicles within range of the
WAND.
Step 15: Connect the DOUBLE SPADE CON-
NECTORS to the battery terminals (RED WIRES to
POSITIVE (+) battery terminal and BLACK WIRES
to NEGATIVE (–) battery terminal). Turn power on,
do not activate operator yet. Wait 60 seconds, then
activate the operator and test the WAND.
NOTE: If you have other accessories connected to your
battery with double spade connectors you may need
to connect a double spade connector to a double spade
connector in order to
connect all the acces-
sories.