User Guide
11
TECHNICAL SPECIFICATIONS:
• Power supply: 8-26 Vac/dc.
• Current consumption: 1.5 mA typical.
• Relay rating: Latching relay
Nominal switching capacity (resistive load) 1 Amp 30 Vdc, 0.5 Amp 125 Vac
Max. switching power (resistive load) 30 Watt, 62.5 V A
Max. switching voltage 110 Vdc, 125 Vac
Max. switching current 1 Amp
• Relay Trip Time: 2 seconds
• Operating Temperature: -25°F (-14°C) to 125°F (69°C)
• Dimensions: 1-3/4” (44.5 mm) diameter x 16.5” (42 cm) long.
• Adjustable range: 3 -12 feet typical installation.
• Very low power consumption, ideal for battery application.
Trouble Shooting: Make sure all connections are correct.
If the WAND is not working:
1. Make sure the Range Adjustment is set at maximum range.
2. Disconnect the power to the WAND.
3. Reconnect the power to the WAND and make sure that no metal object or vehicle is moving around
the WAND for 60 seconds while it is calibrating.
4. Activate the gate operator and test the WAND to verify that it is working properly.