User's Manual

32
Mighty Mule 202
Setting the Open Position Limit
In the PUSH-TO-OPEN application your Mighty Mule 202 has two Limits...
1. CLOSED Limit setting: (Gate in the CLOSED POSITION / FACTORY SET & NOT ADJUSTABLE) The closed
limit is the opener fully retracted and thegate in the closed position.
2. OPEN Limit setting: The OPEN Limit setting (gate in the OPEN POSITION). To achieve optimum open
position, you are required to complete the following STEPS:
Step 1
If not already ON slide the ON/OFF switch on the Control Box to the ON position and make sure the
arms are in the CLOSED POSITION (fully retracted).
Step 2
Press and HOLD the FIRST Opener OPEN button on the control board and be prepared to RELEASE
the button when the gates reached the desired open position/limit. Use the JOG OPEN and CLOSE
buttons to "fine tune" the gate position if neccessary.
Step 3
Repeat STEP 2 for the SECOND Opener.
Step 4
NOTE: The opener Push-Pull tubes must be extended more than 7 inches to set limits.
With the gates in in the desired open positions PRESS and HOLD the SET LIMIT button until the buzzer
and RED Light come on. Then release the button.
Step 5
NOTE: When the control box cover is removed the receiver range is reduced to less than 5 feet.
Press the transmitter button once and allow the gates to fully close. The alarm will beep once when
both gates reach the CLOSED LIMIT. This indicates the LIMITS for both arms are learned and stored in
memory
Step 6
Press the transmitter button and allow the gates to fully open to verify that they stop at the desired
positions. Repeat STEPS 2-5 if correction is needed.
Note: Must have a transmitter that operates the gate. If not see 'Setting Your Personal
Transmitter Code' on page 29.
MIN
MAX
OFF
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
120
SEC.
STALL FORCE
OPEN < JOG > CLOSE
PWR.
SET
LIMIT
1st OPR.
2nd OPR.
STATUS
AUTO CLOSE
FIRST Opener
JOG Buttons
SET LIMIT Button SET LIMIT Light
SECOND Opener
JOG Buttons
for PUSH-TO-OPEN installation