User's Manual
26
Mighty Mule 202
Step 7
Plug the transformer into the electrical outlet. (Use
of a surge protector with the transformer is strongly
recommended - not included)
If electrical outlet is located outdoors, outlet and
transformer should be protected by a weatherproof
cover.
Step 6
At the AC outlet strip
1
/2" of insulation from the ends
of the low voltage wire. Attach these stripped ends to
the transformer terminals.
A dab of household petroleum jelly on each terminal
will help prevent corrosion.
We suggest crimping a spade tongue terminal (not
provided) to the end of each wire before attaching it to
the transformer.
Make sure the exposed wires do not touch each
other!
Step 5
Strip
3
/16" off the ends of the low voltage wire and twist
tightly. Attach these ends to the '14VAC or SOLAR'
terminals located on the terminal block (see illustration
at right). Be certain not to let the exposed wires
touch each other!
Insert one transformer wire into a '14VAC or SOLAR'
terminal. Insert the other transformer wire into the
remaining '14VAC or SOLAR'
terminal. The transformer wires
can be connected to the '14VAC
or SOLAR' terminals regardless of
color.
Tighten set screws against exposed
end of wires. A dab of household
petroleum jelly on each terminal will
help prevent corrosion.
SURGE PROTECTOR
Transformer
VAR5
VAR6
K1
PF1
K2
BATT +
BATT –
K3
K4
VAR4
VAR3
VAR2
VAR1
MIN
MAX
OFF
JP1
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
120
SEC.
GTO Inc. Tallahassee, FL
R4722
STALL FORCE
OPEN < JOG > CLOSE
PWR.
SET
LIMIT
1st OPR.
2nd OPR.
STATUS
AUTO CLOSE
SFTY.
EXIT
CYCLE
EDGE
SENSOR
COMMON
LOCK+
LOCK–
WHT
GRN
RED
BLK
WHT
GRN
SECOND OPR.FIRST OPR.
RED
BLK
14 VAC
OR
SOLAR
ON OFF
Low Voltage Wire from
Transformer or Solar
VAR6
B
K3
K4
WHT
GRN
SECOND OPR.
RED
BLK
14 VAC
OR
SOLAR
ON OFF
Low Voltage Wire
from Transformer
or Solar Panel