Manual
15The DrawingBoard VI Tablet Customization
Selecting a Pre-Programmed Setup
There are three pre-programmed setups available with DrawingBoard VI:
GTCO DP5 High Resolution Binary
Summagraphics MM 1201
CalComp 2000 ASCII
These setups are commonly used within software applications as required
tablet formats. They are stored in Save Areas Default, 2, and 3, respec-
tively. Check the manual that came with your software package to see if
your application requires one of these pre-programmed setups. The
Default setup is available when you power on the digitizer.
To select one of the other setups:
1 Turn on Configuration Mode by clicking on the Config/Exit
key.
2 Click on the desired Restore key.
3 Click on the Config/Exit key again to exit Configuration Mode.
The new setup is activated.
The following table lists the tablet options used by the pre-programmed
setups.
PointTrackRunMode
960096009600Baud Rate
788Data Bits
EvenOddNoneParity
125 pps150 pps125 ppsData Rate
200 lpi500 lpi1000 lpiResolution
Format 0Format 30Format 23Output Format
CalComp 2000
ASCII
Summagraphics
MM 1201 Binary
GTCO DP5
High Resolution
Binary
Emulation
Default Save 2 Save 3