User Manual

Page 8 of 9
Precautions
Storage Condition
This product should be stored without opening the packing, and under temperature 0-60 °C and humidity 30-70% RH. It
should be used within 15 months after reception.
ElectroStatic Discharge (ESD)
This product is sensitive to ElectroStatic Discharge (ESD). Observe precautions for handling electrostatic sensitive devices.
Such precautions are described in the ANSI/ESD S20.20, IEC/ST61340-5, JESD625-A or equivalent standards.
Module Reflow Installation
For RoHS/Pb-free applications, Sn96.5/Ag3.0/Cu0.5 solder is recommended.
Profile Feature Recommended Parameters
Ramp-up rate before liquidous < 2°C / second
Preheat 150-200°C 60-90 seconds
Maximum time at liquidous 40 – 80 seconds
Maximum peak temperature 230° - 240°C (below 250°C)
Ramp-down rate < 6°C / second
Ordering Information
Part Number FW Code Available Description
EC864FPA
Please check with
your sales rep
WiBlue module with integrated PCB antenna
Revision History
Rev. Date Description By
01 2015-09-02 Initial release Paul
02 2015-09-22 Updated Module Outline Paul
03 2016-06-29 Modified block diagram and added detail descriptions Paul