Datasheet
34
High performance passive taps
and splitters with F connector
technology for installation of
wideband cable distribution
networks. Designed as single
taps, double taps or multiple
taps as well as splitters with
2, 3 and 4 connections, they
ensure economical planning
of distribution networks.
All components fulfi l the higher
shielding rating required for
class A according to the stan-
dard EN 50083-2/-4 and are
decoupled to prevent hum.
1) at 40 MHz, -1.5 dB per octave
Splitter SR 812 SR 610 SR 407 SR 305 SR 203
No. of outputs 8 6 4 3 2
Frequency range 5 – 1000 MHz 5 – 1000 MHz 5 – 862 MHz 5 – 862 MHz 5 – 862 MHz
Splitt-loss 5 – 40 MHz
40 – 470 MHz
470 – 862 MHz
11.0 dB
11.0 dB
12.5 dB
9.3 dB
9.8 dB
10.5 dB
7.4 dB
7.4 dB
7.4 dB
5.5 dB
5.5 dB
5.5 dB
3.4 dB
3.4 dB
3.4 dB
Isolation 5 – 40 MHz
40 – 470 MHz
470 – 862 MHz
24 dB
24 dB
20 dB
20 dB
22 dB
20 dB
16 dB
23 dB
23 dB
16 dB
20 dB
20 dB
20 dB
23 dB
23 dB
Return-loss 5 – 40 MHz
40 – 470 MHz
470 – 862 MHz
20 dB
18 dB
18 dB
18 dB
18 dB
18 dB
> 14 dB
> 20 dB
1)
> 20 dB
1)
> 14 dB
20 dB
1)
20 dB
1)
> 16 dB
20 dB
1)
20 dB
1)
Connectors F connector F connector F connector F connector F connector
Single-Tap TR 116 TR 112 TR 108
No. of outputs 1 1 1
Frequency range 5 – 862 MHz 5 – 862 MHz 5 – 862 MHz
Tap-loss 5 – 40 MHz
40 – 470 MHz
470 – 862 MHz
16.0 dB
16.0 dB
16.0 dB
12.0 dB
12.0 dB
12.0 dB
8.5 dB
8.5 dB
8.5 dB
Through-loss 5 – 40 MHz
40 – 470 MHz
470 – 862 MHz
0.8 dB
0.5 dB
0.8 dB
1.0 dB
0.7 dB
1.0 dB
1.8 dB
1.6 dB
1.8 dB
Return-loss 5 – 40 MHz
40 – 470 MHz
470 – 862 MHz
> 14 dB
> 20 dB
1)
> 20 dB
1)
> 14 dB
> 20 dB
1)
> 20 dB
1)
> 14 dB
> 20 dB
1)
> 20 dB
1)
Directional-loss 5 – 40 MHz
40 – 470 MHz
470 – 862 MHz
> 30 dB
> 26 dB
> 26 dB
> 30 dB
> 30 dB
> 26 dB
> 22 dB
> 30 dB
> 22 dB
Connectors F connector F connector F connector
Double-Tap TR 216 TR 212 TR 208
No. of outputs 2 2 2
Frequency range 5 – 862 MHz 5 – 862 MHz 5 – 862 MHz
Tap-loss 5 – 40 MHz
40 – 470 MHz
470 – 862 MHz
16.5 dB
16.5 dB
16.5 dB
12.5 dB
12.5 dB
12.5 dB
8.5 dB
8.5 dB
8.5 dB
Through-loss 5 – 40 MHz
40 – 470 MHz
470 – 862 MHz
1.4 dB
0.8 dB
1.4 dB
1.4 dB
1.2 dB
1.8 dB
3.7 dB
2.8 dB
3.4 dB
Isolation 5 – 40 MHz
40 – 470 MHz
470 – 862 MHz
40 dB
40 dB
36 dB
40 dB
40 dB
36 dB
26 dB
26 dB
22 dB
Return-loss 5 – 40 MHz
40 – 470 MHz
470 – 862 MHz
> 14 dB
> 20 dB
1)
> 20 dB
1)
> 14 dB
> 20 dB
1)
> 20 dB
1)
> 14 dB
> 20 dB
1)
> 20 dB
1)
Directional-loss 5 – 40 MHz
40 – 470 MHz
470 – 862 MHz
> 26 dB
> 30 dB
> 26 dB
> 28 dB
> 28 dB
> 22 dB
> 18 dB
> 18 dB
> 16 dB
Connectors F connector F connector F connector