Datasheet
32
AR 4218, AR 4298
Distribution amplifi ers for single and master antenna systems.
Frequency range up to 862 MHz. Output adjustable with variable
level controller. 230 V mains voltage.
AR 5218, AR 5298
Distribution amplifi ers for single and master antenna systems.
Frequency range up to 862 MHz. Return-path up to 65 MHz either
active or passive switchable. Output level and equalization adjustable
with variable controllers. 230 V mains voltage.
AR 4218 AR 4298
Frequency range 40 – 862 MHz 40 – 862 MHz
Gain 21 dB 29 dB
Noise fi gure typ. 6 dB 6 dB
Output level, IMR = 60 dB
IMR 2 acc. EN 50083-3
IMR 3 acc. EN 50083-3
IMR 3 acc. EN 50083-5
CSO Cenelec 42 channels 862 MHz
CTB Cenelec 42 channels 862 MHz
100 dBμV
107 dBμV
113 dBμV
97 dBμV
100 dBμV
105 dBμV
109 dBμV
115
dBμV
101 dBμV
101 dBμV
Attenuator 0 to -20 dB 0 to -20 dB
Mains voltage (50 - 60 Hz) 230 V AC 230 V AC
Power consumption 3 W 5 W
RF connectors F connectors F connectors
Weight approx. 700 g approx. 700 g
Dimensions (W x H x D) 170 x 90 x 50 mm 170 x 90 x 50 mm
AR 5218 AR 5298
Frequency range 85 – 862 MHz 85 – 862 MHz
Frequency range return-path 5 – 65 MHz 5 – 65 MHz
Gain 21 dB 29 dB
Gain return-path 19 dB 24 dB
Noise fi gure typ. 6 dB 6 dB
Output level, IMR = 60 dB
IMR 2 acc. EN 50083-3 forward
return
IMR 3 acc. EN 50083-3 forward
return
IMR 3 acc. EN 50083-5 forward
return
CSO Cenelec 42 channels 862 MHz
CTB Cenelec 42 channels 862 MHz
100 dBμV
102 dBμV
107 dBμV
107 dBμV
113 dBμV
113 dBμV
97 dBμV
100 dBμV
105 dBμV
102 dBμV
109 dBμV
107 dBμV
115
dBμV
113
dBμV
101 dBμV
101 dBμV
Attenuator 0 to -20 dB 0 to -20 dB
Adjustable line equalization 0 to 18 dB 0 to 18 dB
Mains voltage (50 – 60 Hz) 230 V AC 230 V AC
Power consumption 4.5 W 6 W
RF connectors F connectors F connectors
Weight approx. 700 g approx. 700 g
Dimesions (W x H x D) 170 x 90 x 50 mm 170 x 90 x 50 mm