Users Manual
©2020 GSL Solutions, Inc. IntelliVault Training Guide v.509.5 20201116
18
i. Check connections at both ends of USB cable
1. Move USB cable to another port on back of workstation
ii. Still no LEDs
1. Swap just the IntelliPad with a known working IntelliPad from another workstation
2. Wait 30-60 seconds
3. If the original IntelliPad starts working but the one moved to the original workstation
does not
a. Call GSL Support for a replacement USB cable
4. If the original IntelliPad does not work on moved-to workstation
a. Call GSL Support for a replacement IntelliPad
User Permissions
Each role has a set of User Permissions which allows appropriate access to IntelliSys. In certain
operations, actions will be visible only to users whose roles have the appropriate Permissions; in other
operations where the action is visible, only users with appropriate Permissions are allowed access to the
action.
To Manage User Roles – Each Role has certain User Permissions assigned to it:
1. Navigate to Admin > Roles
2. Press Search to view all Roles or type a Role name and press Search
3. Please contact GSL to change Permissions