User Manual

Repeater User Manual
SmartCell Repeater
16
1900MHz AMP Unit is basically complied with PCS Band block, where maximum three
non-contiguous filtering configurations are available. Each sub block is adjustable per
1.25MHz bandwidth step up to 20MHz. Following table shows user selectable channel
numbers.
BAND
DL CENTER
[MHz]
CHANNEL BAND
DL CENTER
[MHz]
CHANNEL
A
A1
1931.25 25 guard 1965 700
1932.5 50
E
1966.25 725
1933.75 75 1967.5 750
guard 1935 100 1968.75 775
A2
1936.25 125 guard 1970 800
1937.5 150
F
1971.25 825
1938.75 175 1972.5 850
guard 1940 200 1973.75 875
A3
1941.25 225 guard 1975 900
1942.5 250
C
C1
1976.25 925
1943.75 275 1977.5 950
guard 1945 300 1978.75 975
D
1946.25 325 guard 1980 1000
1947.5 350
C2
1981.25 1025
1948.75 375 1982.5 1050
guard 1950 400 1983.75 1075
B
B1
1951.25 425 guard 1985 1100
1952.5 450
C3
1986.25 1125
1953.75 475 1987.5 1150
guard 1955 500 1988.75 1175
B2
1956.25 525
1957.5 550
1958.75 575
guard 1960 600
B3
1961.25 625
1962.5 650
1963.75 675