* Move the closest indoor service antenna farther away
from the outside Donor antenna.
* Close the repeater door if opened and verify that the
closest indoor coverage antenna is not in the same roo
m as the repeater.
Field Replace
able module
failure
Mismatch of AMP unit
and filter service in DF
M
* Call GST's Tech Support Team to verify all the setting
s are correct.
Tamper Dete
cted
Change of mounting i
nformation in the Syst
em
* Wait 5 minutes to clear alarm automatically.
* If you want to disable, you can on the Alarm Configur
ation page.
Communicati
on Failure
Bad connection of NM
S board and AMP unit
* SNMP board or AMP unit need to reset.
* Open the rear cover and check the each cable.
Power Suppl
y out of rang
e
The internal Power Su
pply detects improper
Voltage
* If the system is working fine, disable the alarm on th
e Alarm Configuration page.
* Call to GST's Tech Support Team to verify that all the
settings are correct.
Over Temper
ature
Internal AMP tempera
ture exceeds the Tem
perature Limit
* Verify the Temperature Limit is set between 176 °F ~
201 °F on the RF Configuration page. (Default Value is
163°F)
Reset alarm
During reset of the un
it,
* Wait 30 seconds to clear alarm automatically.
Manual Shut
down
During the shutdown
algorithm after re-
check the system is co
mpletely shut downed
.
* Turn OFF/ON the System by pressing ON/OFF button
on the back side panel.
* Reset AMP unit in WebUI.
FAN FAN Failure * Replace FAN.