User's Manual
User Manual
SmartCell Repeater
14
3. SETUP
3.1 Equipment Needed for Repeater Setup
Paramete
r
Item
Q
uantit
y
Remark
Major Component SmartCell Repeater 1 EA Provided by GST
Additional
Components
Wall Mountin
g
Bracket
CD which contains User Manual
and Installation Guide
Ethernet Cable 6.6ft (2m)
Ground Cable 6.6ft (2m)
Ground Sems Screw M4 x 8mm
Bracket Sems Screw M5 x 10mm
Lag Screw 12.7mm x 50.8mm
FEU-AMP RF cable
FEU-Wall Bracket RF cable
Modem-FEU RF Cable
1 EA
1 EA
1 EA
1 EA
4 EA
20 EA
4 EA
8 EA
2 EA
1EA
Provided by GST
Antenna
Donor ANT
Server ANT
1 EA
1 EA
Not Included
RF Cable Antenna connection Cable
T
BD Not Included
T
estin
g
and Measurin
g
Equipment
Spectrum Analyzer 1 EA Not Included
3.1.1 Check points before turning on the Repeater
1) System Power Check: AC electrical power to the repeater should be 110V. Input
electricity only after power verification.
2) Input RF Signal Range: Optimal input RSSI into the repeater is -57dBm ~ -27dBm for
700MHz/850MHz/1900MHz/2100MHz. User should verify input condition of Donor ANT. If the
input RSSI exceeds -27dBm, then external attenuators should be added.
3) Isolation check between DONOR/SERVER ANT: Isolation condition of this equipment is
105dBc (Gain+15dB). The User should check this condition before installation.