User's Manual
User Manual
SmartCell Repeater
12
2.2.5 1900MHz Frequency Selection
<Figure 8> 1900MHz Band Frequency
The 1900MHz AMP module complies with PCS Band blocks, where a maximum of three non-
contiguous filtering configurations are available. Each sub block is adjustable per 1.25MHz
bandwidth steps up to 20MHz. The Following table shows user selectable channel numbers.
BAND
DL CENTER
[MHz]
CHANNEL BAND
DL CENTER
[MHz]
CHANNEL
A
A1
1931.25 25 guard 1965 700
1932.5 50
E
1966.25 725
1933.75 75 1967.5 750
guard 1935 100 1968.75 775
A2
1936.25 125 guard 1970 800
1937.5 150
F
1971.25 825
1938.75 175 1972.5 850
guard 1940 200 1973.75 875
A3
1941.25 225 guard 1975 900
1942.5 250
C
C1
1976.25 925
1943.75 275 1977.5 950
guard 1945 300 1978.75 975
D
1946.25 325 guard 1980 1000
1947.5 350
C2
1981.25 1025
1948.75 375 1982.5 1050
guard 1950 400 1983.75 1075
B
B1
1951.25 425 guard 1985 1100
1952.5 450
C3
1986.25 1125
1953.75 475 1987.5 1150
guard 1955 500 1988.75 1175
B2
1956.25 525
G 1992.5
1225
1957.5 550
1958.75 575
1250
guard 1960 600
B3
1961.25 625
1275 1962.5 650
1963.75 675