3) Isolation check between DONOR/SERVEICE ANT
Isolation condition of this equipment is 105dBc (Gain+15dB). User should check
its condition before installation.
4.1.2. Open for Service
1) Check points before open:
Verification of system installation status :
Electricity, In/Out antennas, cable connection, and equipment mount status.
Verification of system accessories :
User should check all necessary accessories.
Check receipt signal level :
Installer should check whether environmental conditions are in accordance
with system specification to ensure that system operation will be optimized.
2) Check points after open:
Check external LED
RUN: Green light ON (Off: all lights off)
ALARM: Green light in normal status, Red light in alarming
SHUT DOWN: Green light in normal status, Red light in Shutdown status