Control
Gain Balance Control On/Off Equalizes Uplink and Downlink Gain
Gain Balance Value 0dB to 15dB Subtract Uplink Gain by G/B Value
Shutdown Control On/Off Shutdown if Major Alarm is Reported
Auto Gain Setting On/Off Automatic Gain Setting for the Repeater
Auto Oscillation Control On/Off Prevents Oscillation
Temperature Display 32 to 260.6 Degrees Internal Repeater Temperature
AMP Temperature Upper Limit 0 to 299 Degrees Threshold for Temperature Alarm
Band Blocks Used/Bandwidth Each AMP The Channel the Repeater will be using
Delay Alarm Report 0 or 5 Minutes
Time Delay of Reporting after Alarm is
Detected
3.4 Troubleshooting
In case of abnormal operation, technician should diagnose abnormality via remote access or
directly connecting to repeater using Ethernet cable. If technician is required to conduct repairs
due to major alarm, repeater should first be powered off, and then technician should prepare
the proper measurement equipment before trying to fix the problem.
3.4.1 Simple Troubleshooting Method
1) Verify LED Status, both on external LED’s as well as internal module LED’s
- Normal operation: Green light on. Alarming: Red LED on.
2) Technician should check external and internal connectors to ensure all connections are tightly
secure. These connectors should be cleaned regularly.
3) If technician thinks there is a serious problem, call technical support.
1-866-9-GST-USA (1-866-947-8872)
3.4.2 Alarm Information
Alarm
Name
What causes this
alarm
Troubleshooting Methods
Downlink
Spurious
emissions
out of spec
Downlink Output Pow
er exceeds Downlink
Upper Limit
* The Downlink Output Power should not exceed the m
aximum composite power spec for this unit.
* If the Downlink Output Power is not exceeding the co
mposite power spec for this unit, try to increase the Do
wnlink Upper Limit on the RF Configuration Page.
* Add equal amounts of Uplink and Downlink attenuati
on until the Downlink Output Power is less than the Do
wnlink Upper Limit.
* Set the ALC Downlink Limit on the RF Configuration P
age to a value lower than the Downlink Upper Limit
Downlink Har
dware failure
Downlink path gain is
6dB less than RSSI pl
* By default, if the Downlink Low Output Variance is se
t to 10dB, the Repeater will not report this alarm.