User's Manual
LED Iindicators
NO Items LED Indications Explanations
1Checking
Alarm Æ GREEN LED Blinking
Power Æ GREEN LED Blinking
Auto Setup
2Normal
Alarm Æ Green LED ON
Power Æ Green LED ON
Standard operation
3Alarm
Alarm Æ GREEN LED Blinking
Power Æ OFF
Low Input Signal from DAU
4Alarm
Alarm Æ GREEN LED Blinking Repeatedly
Power Æ GREEN LED Blinking Repeatedly
Isolation Re-Check
5Alarm
Alarm Æ OFF
Power Æ RED LED ON
Low Input Voltage (Feeding to DAU)
6Alarm
Alarm Æ RED LED ON
Power Æ RED LED ON
Link Fail between DAU and SAU
7Alarm
Alarm Æ Red LED Blinking Repeatedly
Power Æ Red LED Blinking Repeatedly
Shutdown Condition
8Alarm
Alarm Æ RED LED Blinking
Power Æ RED LED Blinking
Lack of Isolation between DAU and SAU
Picture Frame
◆ Picture Size: 4 X 6 [inch]Pull Out
ITEM SPECIFICATIONS REMARKS
DAU 6.22 × 5 × 1.96 H*W*D [inch]
Size
SAU 5.7 × 7.67 × 1.65 H*W*D [inch]
Weight 1.63 lbs each DAU, SAU
Length 196.85 ft RG174/1.5D(2.6mm)
Link Cable
Connector SMA(M) DAU to SAU direction
Power Consumption ≤ 18W
external adaptor
12V/3.5A
Operating Temperature +14°F ~ +122°F
Humidity 0% ~ 95%
ITEM SPECIFICATIONS REMARKS
Frequency Range
Down Link 746 – 756 MHz
Up Link 777 – 787 MHz
Band Width 10MHz
Gain
Down Link 50 ~80dB ±1dB
AGC dynamic Range: 30dB
Up Link 50~ 80dB ±1dB
Composite Output Power
Down Link +13dBm/Total
Up Link +13dBm/Total
Shutdown Level +15dBm±2dB Over 5sec standing
Group Delay < 6usec
EVM (Error Vector Magnitude) DL: < 8% @CPL15dB, UL:12.5% @CPL15dB
Specifications