User Manual
MCPA Outdoor System
12/19
.4 Function
Part
Function
Remark
Major Alarm
Generation
For MPCA
• High Temp Alarm Occurs at 185℉, Shutdown Above 190℉
• DC Fail Alarm @ V-sup < +24Vdc or V-sup > +30Vdc
• Over Power Output Alarm @ Output Power is Larger than
Maximum Power + 0.5dBm±0.5dB
• VSWR Alarm 3:1 (6dB±1dB) @ above +40dBm
• Major Loop Fail – Error in 1st Loop Level
Shutdown
Minor Alarm
Generation
For MPCA
• Normal Operation When this Alarm Condition Disappears
• Minor Loop Fail – Error in Feed Forward Path
No
Shutdown
Monitor for
MCA
• Forward Power (MCPA Monitor Ranges From 33dBm to 54dBm)
Alarm for LNA
• LNA Device Fail Alarm
System Alarm
• PSU AC, DC Fail Alarm (Rectifier Module#1, Module#2,
Module#3 DC Fail Alarm)
• FAN Alarm (FAN Individual with Alarm Sensor)
Door Open Alarm
• Alarm Log Record for the Last 100 Failure Event Records
(Include Alarm Event/Time/Date)
• Dry Contact Main Remote Alarming Optional
• 5 min Alarm Delay