User Manual MCPA Outdoor System MCPA Outdoor System User Manual May, 2012 Version 1.
User Manual MCPA Outdoor System - INDEX - 1. SUMMARY ..................................................................... 4 2. SYSTEM CONFIGURATION ............................................ 5 3. SET UP ...... ........................................................
User Manual MCPA Outdoor System U.S.A. U.S.FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT INFORMATION TO THE USER Caution: A ny c hanges or mo difications t o t his d evice n ot explicitly a pproved b y m anufacturer could void your authority to operate this equipment. NOTE: This equipment has been tested and founded to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules.
User Manual MCPA Outdoor System 1. SUMMARY 1.1 Overview MCPA System was designed to improve communication coverage/service quality and customer satisfaction for mobile handset users in coverage areas such as metropolis, urban areas, high dense area and BTS Cell are target candidates for installation. MCPA (Multi-Carrier Power Amplifier) B ooster system provides high p erformance network u pgrade s olution r anging from highly capital-intensive options 1.
User Manual MCPA Outdoor System 2. System Configuration 2.1 System Description 2.1.1 Linear Technology RF Circuit Composition is Simple Feed Forward of Matched Broad-band Quality Feed Forward Linear Technology Increases Efficiency and Reduces Heat 2.1.2 Modular System If One Sector MCA Module Fails, the Other Sectors Will not be affected Modules Moved In and Out for Easy Replacement, Optimizes Size 2.1.
User Manual MCPA Outdoor System 2.2 System Design and Operation 2.2.
User Manual MCPA Outdoor System [Figure2 Cabinet Front, Rear] [Figure3 System Dimensions] 7/19
User Manual MCPA Outdoor System [Figure4 PSU] 8/19
User Manual MCPA Outdoor System [Figure5 MCA] [Figure6 MCU] 9/19
User Manual MCPA Outdoor System [Figure7 FEU] [Figure8 RF Switch] [Figure9 Bias-T] 10/19
User Manual MCPA Outdoor System 2.
User Manual MCPA Outdoor System .4 Function Part Function Remark • High Temp Alarm Occurs at 185℉, Shutdown Above 190℉ Major Alarm Generation For MPCA • DC Fail Alarm @ V-sup < +24Vdc or V-sup > +30Vdc • Over Power Output Alarm @ Output Power is Larger than Maximum Power + 0.5dBm±0.
User Manual MCPA Outdoor System . SET UP .1 System Set up 1) Check points before system set up a. Verification of system installation status - Electricity, In/out antenna, coaxial cable connection, and equipment mounts status. b. Verification of system accessories - User should check whole necessary accessories. c. Check receipt signal level - User should check whether receipt environmental condition is in accordance with system specification, so that system operation will be optimized.
User Manual MCPA Outdoor System .2 Troubleshooting In case of abnormal operation, technician should diagnose abnormality via remote access or directly connecting to MCPA using Ethernet cable. If technician is required to conduct repairs due to major alarm, MCPA should f irst be powered off, and then technician should prepare the proper measurement equipment before trying to fix the problem. In most cases of major MCPA, GST will simply replace the unit and conduct repairs at the appropriate facility. .2.
User Manual MCPA Outdoor System .2.4 Troubleshooting Item Check Point System input power range Check before system operation System gain range Output power at ANT port Check points before open for service Troubleshooting From BTS (37.8dBm ~ 46.5dBm) : 6Watt ~ 45Watt @ 3Carriers 5.5dB ~ 14.
User Manual MCPA Outdoor System .2.5 Troubleshooting Guide Related to LED Status of each individual module can be determined by the status of the LED (MCU, Rectifier, MCA and FEU). All LEDs should illuminate a green; any other indication requires access to the Status / A larm p age. So me c ommon a larms a nd t here r emedies a re d etailed i n t he fo llowing sections.
User Manual MCPA Outdoor System .2.6 Troubleshooting Guide Related to RF Symptom Check Point Troubleshooting When MCPA does not Check electricity cord work connection status -Re-plug in Adapter cord properly Please Check following status; DL VSWR alarm - Make sure Server Antenna Port is disconnected.
User Manual MCPA Outdoor System Check gain of the unit - If the G ain is d ifferent from normal level, please contact A/S team - It i s possible for connectors to get too tight and Cable connector loose damage the equipment or throughput - Please contact installer or service provider upon verification In case of dropped call or bad signal after set up Check input signal strength in the service area Check RSSI signal strength - Increase output power level of MCPA by adjusting attenuation level - Conta
User Manual MCPA Outdoor System .2.
MPE Information Warning: Exposure to Radio Frequency Radiation The radiated output power of this device is far below the FCC radio frequency exposure limits. Nevertheless, the device should be used in such a manner that the potential for human contact during normal operation is minimized. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna should not be less than 1200cm during normal operation. The gain of the antenna is 20 dBi.