User's Manual
Table Of Contents
FCC ID : U88GSTR1930DT-SPR
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
18
ALARM: Green light in normal status, Red light in alarming②
SHUT DOWN: Green light i③ n normal status, Red light in Shutdown
Number of LED bar on front side of repeater will show input signal level. ⑤
Less than -56dBm: LED 1bar
-56dBm~-48dBm: LED 2bars
-48dBm~-39dBm: LED 3 bars
-39dBm~-31dBm: LED 4 bars
-31dBm~-23dBm: LED 5 bars
Number of LED bar in output power side will show output power signal level
Less than +24dBm: LED 1bar
+25dBm~+26dBm: LED 2 bars
+27dBm: LED 3 bars
+28dBm: LED 4 bars
More than +29dBm: LED 5 bars
<Pic.10> Front LED Indicator
4.2 Troubleshooting
In case, abnormal operation is detected, user should check abnormal parts via remote accessible
function or field debug, then conduct repair after turn it off.
4.2.1 Necessary Testing and Measuring equipment
a. RF Power Meter: 10Watt Max, 50ohm
Report No. : HCT-R07-013 18/33