User's Manual

FCC ID : U88GSTR1924DT-SPR
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 19/35
19
a. Check by external LED
RUN: Green light ON (Off: Green light off)
ALARM: Green light in normal status, Red light in alarming
SHUT DOWN: Green light in normal status, Red light in Shutdown
Number of LED bar on front side of repeater will show input signal level.
Less than -56dBm: LED 1bar
-56dBm~-48dBm: LED 2bars
-48dBm~-39dBm: LED 3 bars
-39dBm~-31dBm: LED 4 bars
-31dBm~-23dBm: LED 5 bars
Number of LED bar in output power side will show output power signal level
Less than +15dBm: LED 1bar
+16dBm~+17dBm: LED 2 bars
+18dBm~+19dBm: LED 3 bars
+20dBm~+22dBm: LED 4 bars
More than +23dBm: LED 5 bars
<Pic.10> Front LED Indicator
4.2 Troubleshooting
In case, abnormal operation is detected, user should check abnormal parts via remote accessible