User Manual
SPRINT User Manual
iDEN 30dBm
8
- Power Amplifier part for power amplifier and Level Monitoring/VSWR monitoring to
adjust desirable output power of Repeater
Downlink frequency contains lots of signals such as Paging signal, DCS etc through Donor ANT.
So Out band signals should be minimized by SAW filters having excellent Roll off characteristics
for the best optimized operation.
<Pic.4> iDEN In-building RF Repeater Downlink Block Diagram
2.2.3 Uplink Path
Uplink Block of iDEN In-building RF Repeater is separated as four (4) parts.
- Filter part for Multiplex four (4) bands as each 800MHz and 900MHz TX/RX in Front End
of Donor/Server
- LNA Part of two(2) paths for processing 800MHz and 900MHz signals
- 800MHz IF Converter part and 900MHz IF Converter part of 5MHz band having Switching
filter parts for selecting each 18MHz and 7MHz.