User's Manual
FCC ID : U88GSTR-825DC-SPR
18/26
a. Check by external LED
RUN: Green light ON (Off: Green light off)①
ALARM: Green light in normal status, Red light in alarming②
SHUT DOWN: Green light in normal status, Red light in Shutdown ③
iDEN ④
Number of LED bar on front side of repeater will show input signal level.
-43 dBm~38dBm: LED 1bar
-37dBm~-33dBm: LED 2 bars
-32dBm~-28dBm: LED 3 bars
-27dBm~-23dBm: LED 4 bars
Up than -22dBm: LED 5 bars
Number of LED bar in output power side will show output power signal level.
+0dBm~+4dBm: LED 1bar
+5dBm~+9dBm: LED 2bars
+10dBm~+14dBm: LED 3bars
+15dBm~+19dBm: LED 4bars
Up than +20dBm: LED 5bars
<Pic.10> iDEN In-building RF Repeater front LED
b. Verification via Debug Program
User should check operation status of repeater system via Debug Program.
c. Verification of operation status
Use should verify following status with Output monitoring terminal, which is provided by