3.2 Electrical and Environmental Specifications
ITEM SPECIFICATION REMARK
Power & Consumption 100 ~ 240 VAC,60Hz
Connector Type N-type female
Size 289X385X180
Weight max 40 lbs
Reliability, MTBF 100,000 hours
Enclosure NEMA4
Operating Temperature
-10 ~ +50
Rel. Humidity 0% ~ 90%
Industry Standards
TIA-97, TIA-98, IS-98D,
IS-2000
Regulatory Approvals FCC, Part24 CDN-IC
Safety Approvals UL1950 or Equiv
3.3 Functions
ITEM FUNCTIONS
Gain Control
• Adjustable DL and UL Gain range 42~82dB
• Display default Gain and current Gain function
AGC
(Auto Gain Control)
• It always operates in Downlink AGC ON status
• To maintain same Downlink output power despite flexible input signal
strength
• To add or subtract Attenuation level referring to AGC Power Limit level.
• Used with the Automatic Setup (Auto Gain Setting)
ALC
(Auto Level Control)
• To limit output power as far as default range
• Used for DAS configuration and when oscillation/isolation is a concern
• Automatic Gain decrement when output power of repeater is higher
than default level
• Automatic Gain recovery when output power of repeater is reduced