Cause The CIM module is defective.
Remedy Contact Grundfos.
Related information
2.2.4 Installing a communication interface module
8.19 Code 163 (Drive unit configuration
fault)
Alarm code 163 is shown on the display.
The alarm symbol on the display turns red, but
the pump's operating mode is unchanged.
Alarm code Drive unit configuration fault is
displayed in Grundfos GO Remote.
Cause The configuration of the motor-
drive unit is incorrect.
Remedy Reconfigure the phase setting
on the unit using Grundfos GO
Remote.
8.20 Code 165 (Signal fault)
Alarm code 165 is shown on the display.
The alarm symbol on the display turns red and
the pump stops.
Alarm code Signal fault is displayed in Grundfos
GO Remote.
Cause The signal from the sensor is out
of the configured range.
Remedy Go to Settings > Level
Control in Grundfos GO
Remote and ensure that the
configured range corresponds
to the physical application
type.
Change the sensor, if needed.
8.21 Code 191 (High water level)
Alarm code 191 is shown on the display.
The alarm symbol on the display turns red, but
the pump's operating mode is unchanged.
Alarm code High water level is displayed in
Grundfos GO Remote.
Cause
The defined start level did not
start the pump.
Remedy Check and configure the
sensor for start level.
Cause The pump is not big enough to
remove the water.
Remedy Contact Grundfos or an
authorised service workshop.
Related information
3.6 Configuring the IO terminals using Grundfos GO
Remote
8.22 Code 205 (Level switch inconsistency)
Alarm code 205 is shown on the display.
The alarm symbol on the display turns red and
the pump stops.
Alarm code Level switch inconsistency is
displayed in Grundfos GO Remote.
Cause A float switch could be defective
or stuck.
Remedy Check the functionality of
each float switch.
Related information
3.6 Configuring the IO terminals using Grundfos GO
Remote
8.23 Code 220 (Contactor wear out)
Warning code 220 is shown on the display if you
press the Up or Down button.
Alarm code 220 is shown on the display.
The alarm symbol on the display turns red and
the pump stops.
The warning symbol on the display turns yellow
and the pump's operating mode is unchanged.
Alarm code or warning code Contactor wear
out is displayed in Grundfos GO Remote.
Cause
The contactor has reached its
maximum number of operating
cycles and is worn out.
Alarm: The contactor is worn out
and the pump cannot start.
Remedy Replace LC 231. Contact
Grundfos.
Cause The contactor is approaching its
maximum number of operating
cycles and must be replaced.
Warning: The contactor is close to
being worn out and the pump will
be unable to start.
Remedy Order a new LC 231 to avoid
downtime. Contact Grundfos.
Related information
6.15.4 Setting the motor protection with Grundfos
GO Remote
27