Installation Guide
5
Fig. 1 MQ water supply system. Protective cover is required for outdoor use.
6. Operating conditions
TM04 3648 4908
Base plate
Drain plug
Suction port
Priming plug
Discharge port
Control panel
Pressure tank
cover
End-cover
plug
Protective cover
(accessory)
MQ 3-35 MQ 3-45
Maximum flow rate [gpm] 22
Maximum pressure [psi] 51 65
Maximum system pressure [psi] 108
Maximum suction lift [ft]; see page 49 25
Minimum ambient temperature [°F]/[°C] 32/0
Maximum ambient temperature [°F]/[°C] 113/45
Minimum liquid temperature [°F]/[°C] 32/0
Maximum liquid temperature [°F]/[°C] 95/35
Net weight [lbs] 29
Sound pressure level [dB(A)] < 70
Tank volume [oz] 13.5
Air pressure in tank [psi] 22 to 25
Connections 1" NPT
Priming and drain plugs 3/8" GAS
Grundfos.bk Page 5 Wednesday, July 1, 2009 3:20 PM