ALPHA2 Data Sheet
Table Of Contents
- 1. Cross-reference charts
- 2. Performance ranges
- 3. Product range
- 4. Identification
- 5. Applications
- 6. Technical data
- UP 10-16 Comfort PM, PM Auto
- UP 15-10 B5/B7
- UP 15-10 BUC5/BUC7
- UP 15-10 F/FR
- UP Comfort System
- UP 15-18 B5/B7
- UP 15-18 BUC5/BUC7
- UP 15-29 SU/SF
- UP 15-35 SUC
- UPS 15-35 SUC/SFC
- UP 15-42 B5/B7
- UP 15-42 BUC5/BUC7
- UP 15 MixiMizer™
- UP 15-42 F/FR
- UPS 15-42 F
- UP 15 MixiMizer™
- UP variable speed
- UP 15-55 SUC
- UPS 15-55 SFC/SUC/TLC
- UP 15 ALPHA
- UP 15 ALPHA2
- UP 15 ALPHA2
- UPS 15-58 FC/FRC
- UP 15-100 F
- UP 26-64 F
- UP 26 variable speed
- UP 26-96 F/SF
- UP 26 variable speed
- UP 26-99 F/SF
- UPS 26-99 FC/SFC
- UP 26-116 F/SF
- UP 26-120 U
- UPS 26-150 F/SF
- UP 43-44 F/BF
- UPS 43-44 FC/BFC
- UP 43-70 F
- UP 43-75 F/BF
- UPS 43-100 F/SF
- UP 43-110 F
- UPS 50-44 F
- UPS 50-60 F/SF
- UP 50-75 F
- 7. Accessories
- 8. Grundfos Product Center
Applications
UP Series
5
37
ALPHA2
The Grundfos ALPHA2 is the next generation of
energy-efficient wet-rotor circulator pumps. By
incorporating a permanent magnet motor design,
power consumption is now reduced by a minimum of
50 %.
With the AUTO
ADAPT
™ feature, ALPHA2 will
automatically analyze the system demands and adjust
head and/or flow rate requirements to meet changing
heating demands.
Fig. 3 ALPHA2
Standard features
• Stainless steel or cast iron construction
• permanent magnet motor design
• easy push-button hydraulic selection
• seven hydraulic selection options:
– three fixed speeds
– three constant pressures
– AUTO
ADAPT
™
• easy-to-read LED display
– flow rate indicator (gpm)
– power consumption (watt)
– hydraulic selection
• nut capture flange
• metallurgical options
– cast iron (F or FR)
– stainless steel (F)
• line cord or conduit connection options.
Maximum operating pressures
Maximum operating temperatures
Note: The maximum glycol concentration with clean
water is 0 % glycol @ 36 °F (2 °C). A hydraulic
performance change can be expected.
Fig. 4 Family curves for ALPHA2, all models (ALPHA2 is
a variable-speed pump with AUTO
ADAPT
™)
TM06 7558 4016 / TM06 7586 4016
Liquid temperature Min. inlet pressure
167 °F (75 °C) 0.75 psi (0.05 bar)
194 °F (90 °C) 4.06 psi (0.28 bar)
230 °F (110 °C) 15.7 psi (1.08 bar)
Ambient temperature Liquid temperature
[°F (°C)] Min. [°F (°C)] Max. [°F (°C)]
+32 (0) +36 (+2) +230 (+110)
+50 (+10) +50 (+10) +230 (+110)
+68 (+20) +68 (+20) +230 (+110)
+86 (+30) +86 (+30) +230 (+110)
+95 (+35) +95 (+35) +194 (+90)
+104 (+40) +104 (+40) +158 (+70)
TM06 7989 4316
4>86*30@
>IW@
+
4>PñK@
>P@
+
$/3+$
+]