ALPHA2 Data Sheet
Table Of Contents
- 1. Cross-reference charts
- 2. Performance ranges
- 3. Product range
- 4. Identification
- 5. Applications
- 6. Technical data
- UP 10-16 Comfort PM, PM Auto
- UP 15-10 B5/B7
- UP 15-10 BUC5/BUC7
- UP 15-10 F/FR
- UP Comfort System
- UP 15-18 B5/B7
- UP 15-18 BUC5/BUC7
- UP 15-29 SU/SF
- UP 15-35 SUC
- UPS 15-35 SUC/SFC
- UP 15-42 B5/B7
- UP 15-42 BUC5/BUC7
- UP 15 MixiMizer™
- UP 15-42 F/FR
- UPS 15-42 F
- UP 15 MixiMizer™
- UP variable speed
- UP 15-55 SUC
- UPS 15-55 SFC/SUC/TLC
- UP 15 ALPHA
- UP 15 ALPHA2
- UP 15 ALPHA2
- UPS 15-58 FC/FRC
- UP 15-100 F
- UP 26-64 F
- UP 26 variable speed
- UP 26-96 F/SF
- UP 26 variable speed
- UP 26-99 F/SF
- UPS 26-99 FC/SFC
- UP 26-116 F/SF
- UP 26-120 U
- UPS 26-150 F/SF
- UP 43-44 F/BF
- UPS 43-44 FC/BFC
- UP 43-70 F
- UP 43-75 F/BF
- UPS 43-100 F/SF
- UP 43-110 F
- UPS 50-44 F
- UPS 50-60 F/SF
- UP 50-75 F
- 7. Accessories
- 8. Grundfos Product Center
Applications
UP Series
5
38
Additional technical data
ALPHA2 control display
Fig. 5 Control panel
Supply voltage: 1 x 115 V - 10 %/+ 10 %, 60 Hz
Motor protection: No protection required.
Enclosure class:
Indoor use only, IP42
CSA enclosure type 2
Insulation class: F
Relative humidity: Max. 95 %
Max. outlet pressure: 150 psi (10.34 bar)
Sound pressure level: 43 dB (A)
Ambient temperature: +32 °F (0 °C) to +104 °F (+40 °C)
Liquid temperature: +36 °F (+2 °C) to +230 °F (+110 °C)
Max. glycol
concentrations:
50 % glycol @ 36 °F (2 °C)
A hydraulic performance change can be
expected.
Watt readings: Accuracy +/- 1 watt
Flow rate indicator:
Provides a relative indication of flow rate –
should not be used in lieu of a flowmeter.
Check valve:
Use of a check valve may reduce the pump
hydraulic performance (up to -10 %).
Use a check valve in parallel pumping
applications.
TM04 3421 3511
Pos. Description
1
Display showing the power consumption in watt or the flow
rate
Light field indicating high and low flow rate
2 Production code:
• 1st and 2nd figures: year
• 3rd and 4th figures: week
3 Light field indicating fixed speed
4 Light field indicating constant pressure
5 Light field indicating AUTO
ADAPT
6 Push-button for selection of pump setting