Install Instructions

Table Of Contents
2.4.2 Type key for SCALA1
Example:
SCALA1 . 5- . 25 . 1x230V . 50 Hz . SCHUKO
Description
SCALA1 Type range
3
5
Max. flow rate [m
3
/h]
25
35
45
55
Max. head [m]
1x230V
1x115V
Voltage [V]
50 Hz
60 Hz
Frequency [Hz]
SCHUKO (Type E/F)
No plug
Thailand (Type O)
Australia (Type I)
UK (Type G)
US (Type NEMA 5-15, NEMA 6-15)
Argentina (Type I)
Plug type
3. Receiving the product
3.1 Inspecting the product
On receipt of the product, do the following:
1. Check that the product is as ordered.
If the product is not as ordered, contact the supplier.
2. Make sure that the supply voltage and frequency correspond to
the values stated on the product nameplate.
3.2 Scope of delivery
The box contains the following items:
1 Grundfos SCALA1 pump
1 quick guide
1 safety instructions booklet.
4. Installation requirements
4.1 Location
The product can be installed both indoors and outdoors.
Please observe the following:
Install the product to enable easy inspection, maintenance, and
service.
We recommend that you place the product as close as possible
to the liquid to be pumped.
We recommend that you install the product near a drain or in a
drip tray connected to a drain in order to lead away possible
condensation from cold surfaces.
4.1.1
Installation of the product in a frosty environment
Protect the product from freezing if it is to be installed outdoors
where frost may occur.
4.1.2
Minimum space
The pump requires a minimum space of 495 x 225 x 340 mm (19.5
x 8.9 x 13.4 inches).
Even though the pump does not require much space, we
recommend that you leave enough space for service and
maintenance access.
4.2
Maximum system pressure
Make sure that the system in which the pump is installed
is designed for the maximum pump pressure
The maximum inlet pressure depends on the head at the actual
duty point. The sum of the inlet pressure and the head must not
exceed the maximum system pressure.
We recommend installing a pressure-relief valve to protect the
pump so that the outlet pressure does not exceed the maximum
system pressure.
5. Mechanical installation
WARNING
Electric shock
Death or serious personal injury
Switch off the power supply before you start any work
on the product. Make sure that the power supply
cannot be switched on accidentally.
WARNING
Electric shock
Death or serious personal injury
Mount the product horizontally to avoid condensation
in the electrical insulation inside the control box.
WARNING
Chemical hazard
Death or serious personal injury
Before the pump is used for supplying drinking water,
flush the pump thoroughly with clean water.
WARNING
Biological hazard
Death or serious personal injury
Before the pump is used for supplying drinking water,
flush the pump thoroughly with clean water.
5.1 Positioning and mounting the product
Always place the product in a horizontal position. A higher
inclination can cause electric shock due to condensation
in the electrical insulation inside the control box.
1. Place the product in a horizontal position with a maximum
inclination angle of ± 5 °. The base plate must face downwards.
2. Fasten the product to a solid horizontal foundation by means of
screws through the holes in the base plate.
TM075005
Horizontal foundation
7