Install Instructions

Table Of Contents
9.2.1 External input
This pump allows connecting external input as an additional
condition to the pump operation.
External input may be beneficial in the following situations:
level switch in roof tank filling to stop the pump when the tank is
full
inlet pressure switch to stop the pump in case of raised inlet
pressure
moisture detection switch in irrigation applications to run the
pump only when the ground is dry.
External input must be 24 V digital input and can be connected
through the opening on the pump body. The cable length is limited
to 30 m.
External input can only be set up with Grundfos GO
Remote.
9.2.1.1 Setting up external input
WARNING
Electric shock
Death or serious personal injury
Switch off the power supply before you start any work
on the product. Make sure that the power supply
cannot be switched on accidentally.
WARNING
Electric shock
Death or serious personal injury
The protective earth (PE) of the power outlet must be
connected to the protective earth of the pump. The
plug must have the same PE connection system as
the power outlet.
All electrical connections must be carried out by qualified
persons in accordance with local regulations.
If the power cable is damaged, it must be replaced by the
manufacturer, the manufacturer's service partner or a
similarly qualified person.
Make sure that the electrical installation supports the rated
current [A] of the product. See the nameplate of this
product.
12
3
4
TM075384
Connecting external input
Pos. Description
1 Lid on PCB cover
2 Terminals
3 Cable clip
4 Cable gland
1. Remove the screws and lift the pump cover.
2. Open the lid on the PCB cover.
3. Pull the cable through the gland and the clip.
4. Connect to the terminals.
5. Fix the clip to hold cable in place.
6. Close the lid.
7. Return the pump cover and screw it in place.
8. Power on the pump and connect with Grundfos GO Remote.
15
English (GB)