Use and Care Manual
Table Of Contents
- English (GB)
- 1. General information
- 2. Safety information for working on the product
- 3. Maintenance
- 4. Dismantling the product
- 4.1 Before dismantling the product
- 4.2 Removing the pump cover
- 4.3 Removing the pressure switch
- 4.4 Removing the connection module housing
- 4.5 Removing the membrane
- 4.6 Removing the chamber stack
- 4.7 Removing the shaft seal
- 4.8 Removing the control box cover
- 4.9 Removing the printed circuit board cover inside the control box
- 4.10 Removing the printed circuit board from the control box
- 4.11 Replacing the printed circuit board
- 4.12 Removing the capacitor from the control box
- 4.13 Removing the motor
- 4.14 Removing the motor stool and the flange
- 5. Assembling the product
- 5.1 Fitting the motor stool and the flange
- 5.2 Fitting the motor
- 5.3 Fitting the shaft seal
- 5.4 Assembling the chamber stack
- 5.5 Fitting the chamber stack
- 5.6 Connecting the capacitor to the printed circuit board
- 5.7 Fitting the printed circuit board
- 5.8 Fitting the membrane
- 5.9 Fitting the cover for hydraulic
- 5.10 Fitting the pressure switch
- 5.11 Fitting the pump cover
- 6. Additional information
5.3 Fitting the shaft seal
Do not touch the ceramic faces of the shaft seal.
103
104
4
TM076148
Shaft seal and seal disc
104
103
TM075708
How to correctly hold the shaft seal
1. Lubricate both sealing parts with soapy water.
2. Place the stationary part of the shaft seal (103) in the outer
motor stool (156b).
3. Lubricate the shaft with soapy water.
4. Place the rotating part of the shaft seal (104) on the shaft.
5. Place the washer (102) on the shaft.
5.4
Assembling the chamber stack
Do not touch the inner ceramic faces of the shaft seals
(103) (104).
1. Make sure you have all components ready and place them on
the shaft of the motor unit (150) in the following order.
44a
67
66
44
45
45a
4a
49
4
45
45a
4a
49
4
45
45a
4a
3
102
104
103
49
4
TM075701
Assembling the chamber stack
a. Shaft seal, stationary part (103)
b. Shaft seal, rotating part (104)
c. Diffusor, final (3)
d. Diffusor (4a)
e. Backward bushing for impeller (45a)
f. Impeller (49)
g. Forward bushing for impeller (45)
h. Chamber (4)
i. Inlet part for hydraulic (44)
j. Washer (66)
k. Lock nut (67)
l. O-ring (44a)
5.5 Fitting the chamber stack
Make sure that all the components are on the shaft in the
right order.
1. Once all chambers and impellers are in place, fasten the shaft.
Use a large flat screwdriver at the drive-end and a 13-mm
spanner at the non-drive end. Use a torque of 8 Nm.
TM075695
2. Fit the plug on the nameplate to cover the shaft end.
10
English (GB)