Specification

Table Of Contents
3.2.5 Roof tank filling
1
5
2
3
4
TM075330
Pos. Description
1 Float switch
2 External input (switch) cable
3 Pump
4 Water source (tank)
5 Roof tank
3.3 Electrical connection
The electrical connection and protection must be carried
out in accordance with local regulations. Please also
observe the following requirements:
Make sure that the pump is suitable for the power
supply to which they are to be connected.
The pump must always be correctly earthed.
The plug on the pump must have the same protective
earth (PE) connection system as the power outlet. If
not, use a suitable adapter if allowed by local
regulations.
A pump without plug must be connected to an external
main switch or wired with a plug.
3.4 Motor protection
The pump incorporates current- and temperature-
dependent motor protection. If the pump is blocked or
otherwise overloaded, the built-in thermal switch will cut
out. When the motor has cooled suf
ficiently, it will restart
automatically.
No external motor protection is required.
SCALA
3
10
Installation and operation