Competitive Cross Reference
Table Of Contents
- 1. Cross reference charts
- 2. Performance ranges
- 3. Product range
- 4. Identification
- 5. Applications
- Heating systems
- Domestic hot-water systems
- Cooling systems
- Construction
- Materials of construction
- Installation
- Pumped liquids
- Ambient and liquid temperatures
- Maximum system pressure
- Minimum inlet pressure
- Performance
- ALPHA
- MixiMizer™ - mixing reset pump
- Variable-speed pump
- Comfort System
- UP 10-16 Comfort PM, PM Auto
- 6. Technical data
- UP 10-16 Comfort PM, PM Auto
- UP 15-10 B5/B7
- UP 15-10 BUC5/BUC7
- UP 15-10 F/FR
- UP Comfort system
- UP 15-18 B5/B7
- UP 15-18 BUC5/BUC7
- UP 15-29 SU/SF
- UP 15-35 SUC
- UPS 15-35 SUC/SFC
- UP 15-42 B5/B7
- UP 15-42 BUC5/BUC7
- UP 15 MixiMizer™
- UP 15-42 F/FR
- UPS 15-42 F
- UP 15 MixiMizer™
- UP variable speed
- UP 15-55 SUC
- UPS 15-55 SFC/SUC/TLC
- UP 15 ALPHA
- UP 15 ALPHA
- UPS 15-58 FC/FRC
- UP 15-100 F
- UP 26-64 F
- UP 26 variable speed
- UP 26-96 F/BF
- UP 26 variable speed
- UP 26-99 F/BF
- UPS 26-99 FC/BFC
- UP 26-116 F/BF
- UP 26-120 U
- UPS 26-150 F/SF
- UP 43-44 F/BF
- UPS 43-44 FC/BFC
- UP 43-70 F
- UP 43-75 F/BF
- UPS 43-100 F/SF
- UP 43-110 F
- UPS 50-44 F
- UPS 50-60 F/SF
- UP 50-75 F
- 7. Accessories
- 8. Further product information
Applications
UP Series
5
40
UP 10-16 Comfort PM, PM Auto
The UP 10-16 pump is designed for recirculation of
domestic hot water in single-family homes with
dedicated hot-water return piping. Utilizing a low-noise
permanent magnet motor, energy consumption is
reduced to as little as 5 - 8.5 W. Selecting the Auto
mode ensures that the pump runs only when required.
The result is maximum comfort - no waiting for hot
water plus decreased water and power consumption.
Fig. 9 UP 10-16 APM BU/LC
Applications
• Domestic hot-water recirculation systems in single-
family homes
• small heating systems.
Pumped liquids
• Domestic hot water
• softened water
•clean water.
The pump uses two temperature sensors, one within
the pump and the other connected to the pump by a
cable installed in the hot-water flow pipe. The pump is
installed in the hot-water return pipe.
Fig. 10 UP 10-16 APM pump with built-in temperature
sensor
Three operating modes
100 % mode
• Pump will operate 24/7/365 continuously at full
speed.
Temperature mode
• Pump will keep the water temperature within an
automatically detected range.
Auto mode
• Pump will learn, store and adapt operating times to
home hot water consumption patterns.
Disinfection feature
• Once per week, the pump will run a 15-minute
disinfection cycle.
Vacation feature
If no tappings are detected in a 24-hour period, the
pump will (self-modulate) automatically switch to
standby mode (except for disinfection) and reactivate
to the same consumptive pattern when 2 tappings
occur within a 20-minute time period.
Motor
The motor is single-phase, 12-pole, permanent-
magnet design, impedance-protected, double
insulated, No additional motor protection is required.
Maximum system pressure
145 psi (10 bar).
Ambient and liquid temperatures
The ambient temperature should always be lower than
the liquid temperature, as otherwise condensation may
form in the stator housing.
Liquid temperature: 36 °F (2 °C) to 185 °F (85 °C).
We recommend to keep the operating temperature as
low as possible (e.g. 140 °F (60 °C)) to avoid calcium
precipitation.
TM06 0034 4713TM06 1073 1514
8-20 inches
Max. 8 ft.
Voltage 1 x 115/208-230 V, 50/60 Hz
Power 5 - 8.5 Watts
Enclosure class IP42, type PM: IP44
Insulation class F
Description Material
Stator housing Aluminium
Spherical separator Stainless steel
Rotor can, complete Stainless steel/Tungsten carbide
Rotor, impeller Stainless steel, EPDM, PPO, PFTE, graphite
Pump housing EcoBrass
Isolating valve EcoBrass
Screw Stainless steel
Terminal box cover PC/ABS
Motor cover PPO
Power cable jacket PVC
O-Rings EPDM
Check valve POM
Light Lexan
Insulation cover EPP 55
External sensor cable PC/ABS