UP/UPS Pumps Product Guide

Table Of Contents
Technical data
UP Series
6
88
UP 50-75 F
Approvals
Note: Dimensions in inches unless otherwise stated.
TM03 5545 4412
0 4 8 12 16 20 24 28 32 36Q [US GPM]
0
2
4
6
8
10
12
14
16
18
20
22
24
26
[ft]
H
0 2 4 6 8 Q [m³/h]
0
1
2
3
4
5
6
7
8
[m]
H
UP50-75F
60 Hz
Flow range: 0-41 gpm (0 - 9.3 m
3
/h)
Head range: 0-25 ft (0 - 7.6 m)
Motor: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 32 °F (0 °C)
Max. system pressure: 145 psi (10 bar)
Closed system
Model Volts Amps Watts Hp Capacitor
UP 50-75 F
115 2.15 215 0.289 10 μF / 180 V
230 1.07 220 0.295 2.5 μF / 400 V
UP 50-75 F
TM03 8760 2407
Model
Product number Dimensions [inches (mm)]
Connection type
and size
Shipping weight
[lbs (kg)]
115 V 230 V A B C D E F
UP 50-75 F 52722352 52722353 8.50 (216) 7.50 (191) 5.06 (129) 4.88 (124) 3.50 (89) 4.19 (106)
GF 50 flange
(4) 1/2" dia. bolt holes
15.5 (7.0)