Product range
MAGNA3
3
10
If an external controller is installed, the pump is able to change from one constant curve to
another, depending on the value of the external signal.
The pump can also be set to operate according to the max. or min. curve, like an uncontrolled
pump:
The max. curve mode can be used in periods in which a maximum flow is required. This
operating mode is for instance suitable for hot-water priority.
The min. curve mode can be used in periods in which a minimum flow is required. This
operating mode is for instance suitable for manual night setback if Automatic Night Setback
is not desired.
Constant curve
In systems with pumps operating in parallel.
The multi-pump function enables the control of single-head pumps connected in parallel
(two pumps) and twin-head pumps without the use of external controllers. The pumps in a
multi-pump system communicate with each other via the wireless GENIair connection.
"Assist" menu
Multi-pump setup
System application
Select this control
mode
H
Q