User Guide

Table Of Contents
English (US)
66
13.4 External sensors
13.4.1 Temperature sensor
13.4.2 Pressure sensor
13.5 Adapter
13.6 Cable for sensors
13.7 Blanking flange
A blanking flange is used to blank off the opening when one of the
pump heads of a twin-head pump is removed for service to
enable uninterrupted operation of the other pump. See fig. 67.
Fig. 67 Position of a blanking flange
14. Disposing of the product
This product has been designed with focus on the disposal and
recycling of materials. The following average disposal values
apply to all variants of pumps:
85 % recycling
10 % incineration
5 % depositing.
Dispose of this product or parts of it in an environmentally sound
way according to local regulations.
See also end-of-life information at
www.grundfos.com/product-recycling.
Sensor Type
Measuring
range
[psi (bar)]
Measuring
range
[°F (°C)]
Transmitter
output
[mA]
Power
supply
[VDC]
Process
connection
Product
number
Combined pressure and
temperature sensor
RPI T2
0-232
(0-16)
14 to 248
(-10 to +120)
4-20 12.5 - 30 G 1/2 98355521
Sensor Type
Measuring
range
[psi]
Measuring
range
[bar]
Transmitter
output
[mA]
Power
supply
[VDC]
Process
connection
Product
number
Pressure transmitter RPI
0-9 (0 - 0.6)
4 to 20 12 to 30 G 1/2
97748907
0-15 (0 - 1.0) 97748908
0-25 (0 - 1.6) 97748909
0-35 (0 - 2.5) 97748910
Adapter Product number
Adapter for 1/4" NPT 98344015
Description
Length
[ft (m)]
Product number
Screened cable 6.56 (2.0) 98374260
Screened cable 16.40 (5.0) 98374271
Pump type Product number
MAGNA3 D 65-150 F
MAGNA3 D 80-100 F
MAGNA3 D 100-120 F
98159372
TM06 8518 0817