Install Instructions
11
English (US)
9.1 Electrical data
Supply voltage:
1 X 115/230V 60Hz
1 X 230V 60Hz
Voltage tolerance +/- 6 %
9.2 Approvals
File no. 703194
Deep well - cast iron
Model JP4-47DSA JP4-54DSA JP5-61DSA JP8-62DSA
Max. flow [gpm (m
3
h)] 18 (4.1) 18 (4.1) 21 (4.8) 32 (7.3)
Max. pump head [ft (m)] 145 (44.2) 170 (51.2) 195 (59.4) 200 (61.0)
Max. working pressure [psi (bars)] 116 (8 bars)
Motor power [hp] 1/2 3/4 1 1/2 2
Fluid temp range [°F (°C)] +32 to +95 (0 to +35)
Max. lift [ft suction lift at sea level] 50 70 90 90
Max. ambient temp [°F (°C)] +104 (+40)
Factory pressure switch
setting [psi (bars)]
30/50
(2.1/3.5)
30/50
(2.1/3.5)
50/70
(3.5/4.8)
50/80
(3.5/5.5)
Storage temp range [°F (°C)] +14 to +104 (-10 to +40)
Relative humidity 95%
Max. starts per hour 20
Electrical data 60 Hz
Pump model
P2
Power out
[hp]
SF
Voltage
[V]
In (SFA)
Capacitor
rating
Line fuses
[amps]
1x115V 1x230V 1x115V 1x230V
JP4-47DSA-PS 0.5 1.60 115V/230V 7.09 3.61 50 μF, 250V 8 4
JP4-47ASA-PS 0.5 1.60 115V/230V 8.21 4.22 50 μF, 250V 12 6
JP4-47ASI-PS 0.5 1.60 115V/230V 8.21 4.22 50 μF, 250V 12 6
JP4-54DSA-PS 0.75 1.50 115V/230V 9.20 4.67 50 μF, 250V 12 6
JP4-54ASA-PS 0.75 1.50 115V/230V 10.3 5.25 50 μF, 250V 12 6
JP4-54ASI-PS 0.75 1.50 115V/230V 10.3 5.25 50 μF, 250V 12 6
JP4-61ASA-PS 1 1.40 115V/230V 13.8 7.10 80 μF, 250V 16 8
JP4-61ASI-PS 1 1.40 115V/230V 13.8 7.10 80 μF, 250V 16 8
JP5-61DSA-PS 1.5 1.30 230V - 7.6 31.5 uF, 450V - 10
JP5-61ASA-PS 1.5 1.30 230V - 8.0 31.5 uF, 450V - 10
JP8-62DSA-PS 2 1.25 230V - 8.5 40 μF, 450V - 10
JP8-62ASA-PS 2 1.25 230V - 11.0 40 μF, 450V - 12
JP12-51ASA-PS 3 1.15 230V - 12.0 40 μF, 450V - 16
JP_JP-PS_US.book Page 11 Tuesday, July 19, 2011 8:07 PM