Brochure

www.grundfos.com
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence
Canada
GRUNDFOS Canada Inc.
2941 Brighton Road
Oakville, Ontario
L6H 6C9
Phone: (905) 829-9533
Telefax: (905) 829-9512
U.S.A.
GRUNDFOS Pumps Corporation
17100 West 118th Terrace
Olathe, Kansas 66061
Phone: (913) 227-3400
Telefax: (913) 227-3500
Mexico
Bombas GRUNDFOS de Mexico S.A. de C.V.
Boulevard TLC No. 15
Parque Industrial Stiva Aeropuerto
C.P. 66600 Apodaca, N.L. Mexico
Phone: 011-52-81-8144 4000
Telefax: 011-52-81-8144 4010
Using CIM/CIU with Grundfos products
General CIU 300 data
Supply voltage 24-240 VAC/VDC, –10% / + 15%
Frequency 0 - 60 Hz
Power consumption Max. 11 W
Cable size IEC: 0.2 - 4 mm2, UL: 24-12 AWG
Enclosure class IP 54, according to IEC 60529
Cable entry 6 x M16 Ø4 – Ø10
Operating temperatures –20 °C to +45 °C (–4 °F to +113 °F)
Storage temperatures –20 °C to +60 °C (–4 °F to +140 °F)
Dimensions (H/W/D) 182 x 108 x 82 mm
GENIbus Communication
Protocol GENIbus
Recommended cable type Screened, double twisted-pair
Maximum cable length 1200 m/4000 f
t
BACnet Communication
Transceiver RS-485
Protocol BACnet MS/TP (Master)
Transmission speeds 9.6, 19.2, 38.4, 76.8 kbits/s
BACnet master address 0 – 127
L-CI-SL-006 3/10 (US)
Data points
CIM 300 BACnet
s = available with sensor
s* = available with sensor or TPE
2000
1
on sensor
2
Not standard for Control MPC
MAGNA / UPE
E-Pumps
0.25-7.5 kW
CUE / E-Pumps
11-22 kW
Multi-E
Hydro MPC/
Control MPC
Control
Operating Mode
Setpoint
Control Mode
Relay Control
Status
Operating Mode status
Control Mode Status
Feedback
Alarm/warning information
Bearing Service Information
Measured Data
Power/Energy Consumption
Pressure (Head)
1
s* s*
2
Flow**
s* s*
2
Relative Performance
Speed and Fr
equency
Digital Input/Output
Motor Current
Motor Voltage
Remote Flow s
Inlet Pressure
1
s s
Remote Pressure
1
s s
Level s s s
Motor Temperature
Remote Temperature s s s
Pump Liquid Temperature
s
Bearing Temperatures s
Auxilary Sensor Input s s
Operation Time (Run Time)
Total on time
Number Of Starts
Volume (CUE only) s
Ambient Temperature s
Inlet and Outlet Temperatures s
s
Outlet Pressure
1
s
Feed Tank Level s
Subpump Data
Status information
Alarm information
Operation Time (Run Time)
Speed
Note: E-Pumps = CRE/CRNE/CRIE, MTRE, CME, TPE Series 1000/2000, NBE/NKE
** Estimated flow can be used for monitoring purposes only, but it is not recommend for
controling purposes.
BACnet Network
CIU 300 CIU 300
E-pump 11-22 kW
with CIM 300
built in
MAGNA/UPE Hydro/
Control MPC
GENIbus GENIbus
Using CIM/CIU with Grundfos products
L-CI-SL-006 3/10 (US)