DRAINAGE PUMPS
SPACE REQUIREMENTS
The pumps are supplied with 10 metres
of cable. If the pump is installed in a pit,
the minimum dimensions must be as in
the drawing. The UNILIFT CC is equipped
with a fl oat switch with adjustable cable
length.
LOW SUCTION
It is possible to obtain low suction by
removing the suction strainer with
a screwdriver. This makes the pump
capable of pumping down to a liquid
level of 3mm. The self-prime level is
5mm.
COMPONENTS INCLUDED
The pump is delivered with an adapter
for connection and a non-return valve.
The adapter has ¾”, 1” and 1 ¼” external
threads. The adapter has to be cut to
t the actual discharge pipe. The non
return valve can be fi tted in the adapter.
It prevents backfl ow when the pump is
stopped.
INSTALLATION
ïëë
ðíë
îðëïëë
ììððð
ìëëíëë
./-/
./*+
min/max
oat switch
cable