Brochure
Product Guide
Control panel operation
1
3
5
6
4
2
TM01 9684 2600
Pos. Function Description
1 ON/OFF button
The Pump is started and stopped by
means of the ON/OFF button.
2
Power indicator lights
Indicates that the pump is ready for
operation (green).
3
Indicates that the pump is on
standby (red).
4 Pump ON (green) Indicates that the pump is running.
5 Auto reset (green)
Indicates that the auto reset
function is active. After an alarm,
restarting will be attempted every
30 minutes for a period of 24 hours.
6 Alarm (red)
Indicates that the pump is in alarm
state. Manual resetting is possible
by pressing the ON/OFF button.
MQ
Flow Based Pressure Boosting System
Part
Number
Model PH & V
AMPS P2
Weight
Net
Pounds
Cord
Connection
Plug
Run Start W HP
96860172 MQ 3-35 1X110-120V 8 29 585 0.75 30.1
7.54’ - 2300mm SJTW-A
18 awg
UL Approved NEMA
5-15P - V125
96860195 MQ 3-45 1X110-120V 10 29 725 1 30.2
7.54’ - 2300mm SJTW-A
18 awg
UL Approved NEMA
5-15P - V125
96860201 MQ 3-35 1X220-240V 4 15 565 0.75 30.1
7.54’ - 2300mm SJTW-A
18 awg
UL Approved NEMA
6-15P - V250
96860207 MQ 3-45 1X220-240V 4.8 15 716 1 30.2
7.54’ - 2300mm SJTW-A
18 awg
UL Approved NEMA
6-15P - V250
Product range and electrical data
Dimensions
TM011 9799