Installation Instructions

If it is necessary to
rotate the circulator
head to relocate the
power cord under the
circulator, please follow
the steps below.
11..
Isolate the circulator
from the system water
pressure by closing the
valves on either side of
the circulator. If the
circulator cannot be
isolated, it will be
necessary to turn off
the main water supply.
22..
CAUTION: If operated
recently the circulator
body may be hot. Check
before touching.
6
1.
2.
1
1
2
1
3
3.
4.
5.
6.
7.
33..
CAUTION: If the water supply is not turned off or the circulator is
not isolated from the system, water damage may occur when
proceeding with the next step.
44..
Loosen the brass ring holding the circulator head to the pump
housing. Be careful a small amount of hot water may still leak from
the connection.
55..
Rotate the circulator head until the power cord is directly below it.
66..
Re-tighten the brass ring.
77..
Turn the water back on or open the valves on either side of the cir-
culator.
COMFORT PUMP