TP40-240/2 Products Guide
Table Of Contents
- Mission
- General data
- Cross reference guide: B&G, Taco and Armstrong to Grundfos
- Performance range, TP
- Product range, TP
- Type key, TP
- Applications
- Construction, TP
- TP technical data
- Material specification, TP
- Sectional drawing, TP
- Motor
- Pump
- Surface treatment
- Motor stool
- Pump shaft
- Coupling
- Impeller
- Shaft seal
- Space requirements
- Pumped liquids
- Liquid temperature
- List of pumped liquids
- Legend for notes in the list
- Performance curves
- Data charts
- Submittal data sheet
- Further product documentation
Technical data
17
Dimensions and weights
Note: For information about motor data, see page 22.
Technical data
TM03 7756 4806
Pump type HP
Suc.
disc.
size
Ph
Dimensions [inches]
(mm)
Net wt.
[lbs]
L1 L3 B1 B2 B3 B4 B5 H1 H2 H3 D1 D2 D3 D4 D6 D7
TP50-40/4 1/3
2 (51)
1
14
(356)
7
(178)
6 1/4
(159)
4 7/16
(113)
3 9/16
(90)
3
(76)
4 3/4
(121)
3 1/4
(83)
6 1/4
(159)
18 5/8
(473)
2 1/8
(54)
3 7/16
(87)
4 1/16
(103)
5 1/4
(133)
2 1/2
(64)
3 1/16
(78)
61.5
3 67.5
TP50-80/2 3/4
1
11 1/2
(292)
5 3/4
(146)
6 1/4
(159)
4 7/16
(113)
3 3/4
(95)
3
(76)
4 3/4
(121)
3
(76)
6 3/16
(157)
20 1/16
(510)
2 1/8
(54)
3 7/16
(87)
4 1/16
(103)
5 1/4
(133)
2 1/2
(64)
3 1/16
(78)
71
3
18 5/16
(465)
67.5
TP50-160/2 1 1/2
1
14
(356)
7
(178)
7 1/4
(184)
5 1/8
(130)
4
(102)
4
(102)
4 3/4
(121)
3
(76)
5 15/16
(151)
20 5/16
(516)
2 1/8
(54)
3 7/16
(87)
4 1/16
(103)
5 1/4
(133)
2 1/2
(64)
3 1/16
(78)
86.5
3
19 13/16
(503)
77.5
TP50-240/2 2
1
14
(356)
7
(178)
7 1/4
(184)
5 1/8
(130)
4
(102)
4
(102)
4 3/4
(121)
3
(76)
5 7/8
(149)
20 1/4
(514)
2 1/8
(54)
3 7/16
(87)
4 1/16
(103)
5 1/4
(133)
2 1/2
(64)
3 1/16
(78)
88.5
3
19 5/16
(491)
79.5
Flow range: 8-150 U.S. GPM
Head range: 7-63 ft
Maximum working pressure: 145 PSI
Temperature range: 5°F (–15°C) to 284°* (140°C)
Max ambient air temperature: 104°F (40°C)
Motors: TEFC-Standard, ODP-Optional
Flanges: 1 1/2" 4 bolt with (4) 9/16 dia. holes
VersaFlo®
TP 50