5.6 Winding resistance chart
60 Hz
Pump type Voltage
[Ω] 68ºF - 122ºF (20ºC - 50ºC)
RRARS
1
RS
2
UPS 32-40/4
1 x 115 V 17.8 - 23.2 3.95 - 5.20 9.40 - 12.4
1 x 230 V 70.0 - 91.5 17.0 - 22.2 39.5 - 52.0
3 x 208 - 230 V 180 - 236
3 x 460 V 360 - 470
3 x 575 V 575 - 750
UPS 32-80/2
1 x 115 V 9.55 - 12.6 3.05 - 4.00 6.70 - 8.80
1 x 230 V 19.4 - 25.5 5.45 - 7.10 12.6 - 16.4
3 x 208 - 230 V 44.0 - 57.5
3 x 460 V 83.5 - 110
3 x 575 V 132 - 174
UPS 32-160/2
1 x 115 V 4.15 - 5.45 1.20 - 1.56 2.65 - 3.50
1 x 230 V 8.30 - 10.8 2.20 - 2.90 5.05 - 6.65
3 x 208 - 230 V 26.0 - 34.0
3 x 460 V 53.5 - 70.0
3 x 575 V 84.5 - 110
UPS 40-40/4
1 x 115 V 11.4 - 15.0 2.95 - 3.85 5.60 - 7.35
1 x 230 V 50.5 - 66.5 14.0 - 18.4 25.5 - 34.0
3 x 208 - 230 V 118 - 154
3 x 460 V 234 - 310
3 x 575 V 360 - 475
UPS 40-80/2
1 x 115 V 5.60 - 7.35 1.84 - 2.42 4.50 - 5.90
1 x 230 V 11.0 - 14.4 3.95 - 5.20 8.55 - 11.2
3 x 208 - 230 V 32.0 - 42.0
3 x 460 V 64.0 - 84.0
3 x 575 V 102 - 132
UPS 40-80/4
1 x 115 V 4.15 - 5.45 1.94 - 2.55 3.30 - 4.35
1 x 230 V 8.10 - 10.6 3.05 - 4.00 4.60 - 6.05
3 x 208 - 230 V 46.5 - 61.0
3 x 460 V 90.5 - 118
3 x 575 V 164 - 216
UPS 40-160/2
1 x 115 V 2.85 - 3.75 1.10 - 1.44 1.94 - 2.55
1 x 230 V 5.60 - 7.35 2.02 - 2.66 3.75 - 4.95
3 x 208 - 230 V 22.8 - 30.0
3 x 460 V 45.5 - 59.5
3 x 575 V 72.0 - 95.0
UPS 40-240/2
1 x 230 V 6.80 - 8.95 2.02 - 2.65 3.70 - 4.85
3 x 208 - 230 V 11.0 - 14.4
3 x 460 V 22.0 - 29.0
3 x 575 V 35.0 - 45.5