Brochure
Table Of Contents
- 1. Product introduction
- 2. Product overview
- 3. Product range
- 4. Cross-reference guide
- 5. Construction
- 6. Operating conditions
- 7. Functions
- 8. Technical data
- 9. Curve charts and technical data
- UPS 32-40/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 32-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 32-80/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 32-80/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 32-160/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 32-160/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-40/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 40-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-80/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 40-80/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-80/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 40-80/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-160/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 40-160/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-240/2, 1 ph, 230 V, 60 Hz
- UPS 40-240/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-40/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 50-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-80/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 50-80/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-80/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 50-80/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-160/2, 1 ph, 230 V, 60 Hz
- UPS 50-160/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-240/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 53-55/57, 1 ph, 115 V, 230 V, 60 Hz
- UPS 53-55/57, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 75-69/2, 1 ph, 230 V, 60 Hz
- UPS 75-69/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 80-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 80-80/4, 3 ph, 208-230 V, 60 Hz
- UPS 80-160/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 100-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UP 43-70, 1 ph, 115 V / 230 V, 60 Hz
- UP 43/110, 1 ph, 115 V / 230 V, 60 Hz
- UP 53-45, 1 ph, 115 V / 230 V, 60 Hz
- UP 53-46, 1 ph, 115 V / 230 V, 60 Hz
- 10. Accessories and spare parts
- 11. Further documentation
Cross-reference guide
UP, UPS Series 200
4
9
Bronze version to be used in open systems.
Replacement model requires piping and/or flange modification.
Disclaimer: This cross-reference is a guide only. Use individual technical data sheets for correct comparison.
Manufacturer Model
Port-to-port
length
[in]
Flange size
[in]
Grundfos model
Port-to-port
length
[in]
Flange size
[in]
B&G
2-1/2" 10.00 2.50 UP53-45F
9.88 2.00, 2.50, 3.00
LD3 10.00 3.00 UP53-45F
9.88 2.00, 2.50, 3.00
HD3 10.00 3.00 UP53-46F
9.88 2.00, 2.50, 3.00
PD-35 12.00 3.00 UPS53-55/57F
11.88 2.00, 2.50, 3.00
PD-37 12.00 3.00 UPS53-55/57F
11.88 2.00, 2.50, 3.00
PD-38 14.50 3.00 UPS75-69F
14.00 2.00, 2.50, 3.00
PD-40 14.50 3.00 UPS50-160/2
14.00 2.00
601 11.00 1.00 UPS32-80/2
11.00 0.75 to 1.50
602 11.00 1.00 UPS32-80/2
11.00 0.75 to 1.50
603 11.00 1.00 UPS50-80/2
11.50 2.00
604 11.00 1.25 UPS32-80/2
11.00 0.75 to 1.50
609 11.50 1.50 UPS40-160/2
11.50 1.50
610 11.50 2.00 UPS50-80/4
11.50 2.00
621 13.50 2.00 UPS40-80/4 13.50 1.50
614 13.50 1.50 UPS40-240/2 13.50 1.50
615 13.50 2.00 UPS50-160/2 14.00 2.00
616 13.50 2.00 UPS50-160/2 14.00 2.00
622 13.50 1.50 UPS32-160/2 13.50 1.50
623 13.50 1.50 UPS40-240/2 13.50 1.50
617 13.50 1.50 UPS40-240/2 13.50 1.50
624 14.00 2.00 UPS50-160/2 14.00 2.00
625 14.00 2.00 UPS50-240/2 14.00 2.00
60-11 11.00 1.25 UPS32-80/2
11.00 0.75 to 1.50
60-13 11.50 1.50 UPS40-160/2
11.50 1.50
60-14 11.50 2.00 UPS50-80/2
11.50 2.00
60-15 13.50 1.50 UPS32-160/2 13.50 1.50
60-16 13.50 1.50 UPS32-160/2 13.50 1.50
60-17 13.50 1.50 UPS40-240/2 13.50 1.50
60-19 14.00 2.00 UPS50-160/2 14.00 2.00
60-20 14.00 2.00 UPS50-160/2 14.00 2.00
60-21 14.00 2.00 UPS50-240/2 14.00 2.00