Brochure

Table Of Contents
Curve charts and technical data
UP, UPS Series 200
9
57
UPS 100-40/4, 3 ph, 208-230 V, 460 V, 575 V
, 60 Hz
Note: ETA is calculated as wire-to-water efficiency.
Dimensions
roduct numbers Connections
Electrical data
TM00 9509 0307
Flow range: 30 - 270 gpm
Head range: 1 - 12 ft
Motor: 4-pole, 1.00 Hp
Max. liquid temp (Open): +140 °F
Max. liquid temp.: +248 °F
Min. liquid temp.: +32 °F
Max. system pressure: 145 psi
Net wt: 126.8 lbs (57.5 kg)
Gross wt.: 138.9 lbs (63.0 kg)
Shipping volume: 3.53 ft
3
(0.1 m
3
)
Net wt. bronze: 153.2 lbs (69.5 kg)
Gross wt. bronze: 165.3 lbs (75.0 kg)
Shipping volume bronze: 3.53 ft
3
(0.1 m
3
)
0 50 100 150 200 250 300 Q [US GPM]
0
2
4
6
8
10
12
14
H [ft]
0
1
2
3
4
H [m]
0 10 20 30 40 50 60
Q [m³/h]
1
2
3
0 50 100 150 200 250 300 Q [US GPM]
0
200
400
600
P1 [W]
0
20
40
60
Eta [%]
0.0
0.2
0.4
0.6
0.8
P1 [hp]
3
2
1
Eta
TM02 0732 5100
B2
NPT 1/4
B1
H2
H1
H3
M
D5
D4
D3
D1
B7
B4
B5
L1
L3
D2
Model L1L3B1B2B4B5B7H1H2H3D1D2D3D4D5D6D7 M
UPS 100-40/4
[in] 21.00 10.50 5.75 6.68 5.13 3.94 6.31 4.81 12.31 16.61 4.19 6.19 7.50 9.06 0.75
[mm] 533 267 146 170 130 100 160 122 313 422 106 157 191 230 19 M16
Model type
Product number
Voltage
[V]
Cast Iron Bronze
UPS 100-40/4
(3 ph)
96402934 96402937 208-230
96402935 96402938 460
96402936 96401961 575
Flange size Flange type
4" ANSI 125# R.F. GF100
Speed
Max amps
[A]
P Max
[Watts]
Start amps
[A]
All 3-phase, 460V and 575V pumps are 2-speed only.
Canada only.
208-230V 460V 575V 208-230V 460V 575V
3 2.50 1.24 1.00 570 10.80 5.40 4.32
2 1.38 0.70 0.55 435 5.96 3.05 2.44
11.24▲▲390 5.36 ▲▲
UP 100-40/4
3 ph, 208-230 V, 460 V, 575 V
, 60 Hz