Brochure

Table Of Contents
Curve charts and technical data
UP, UPS Series 200
9
28
UPS 32-80/2, 3 ph, 208-230 V, 460 V, 575 V
, 60 Hz
Note: ETA is calculated as wire-to-water efficiency.
Dimensions
Product numbers Connections
Electrical data
TM00 9494 0697
Flow range: 9 - 67 gpm
Head range: 1 - 25 ft
Motor: 2-pole 0.50 Hp
Max. liquid temp (Open): +140 °F
Max. liquid temp.: +248 °F
Min. liquid temp.: +32 °F
Max. system pressure: 145 psi
Net wt: 35.9 lbs (16.3 kg)
Gross wt.: 41.1 lbs (20 kg)
Shipping volume: 1.70 ft
3
(0.048 m
3
)
Net wt. bronze: 39.2 lbs (17.8 kg)
Gross wt. bronze: 47.4 lbs (21.5 kg)
Shipping volume bronze: 1.70 ft
3
(0.048 m
3
)
0 10 20 30 40 50 60 70 Q [US GPM]
0
5
10
15
20
25
H [ft]
0
2
4
6
H [m]
0 2 4 6 8 10 12 14
Q [m³/h]
1
2
3
0 10 20 30 40 50 60 70 Q [US GPM]
0
100
200
300
P1 [W]
0
20
40
60
Eta [%]
0.0
0.1
0.2
0.3
0.4
P1 [hp]
3
2
1
Eta
TM02 0729 5100
NPT 1/4
M
D5
D3
D2
D1
B7
B4
B5
L1
L3
D4
D6
D7
B2
B1
H2
H1
H3
Model L1L3B1B2B4B5B7H1H2H3D1D2D3D4D5D6D7 M
UPS 32-80/2
[in] 11.00 5.50 5.31 5.56 3.00 3.00 3.19 2.69 9.50 12.12 1.44 2.56 3.14 4.63 0.50 1.81 2.25
[mm] 279 140 135 141 76 76 81 68 241 308 37 65 80 117 13 46 57 M12
Model type
Product number
Voltage
[V]
Cast Iron Bronze
UPS 32-80/2
(3 ph)
96402710 96402715 208-230
96402711 96402716 460
96402712 96402717 575
Flange size Flange type
1.25" non ANSI 2 bolt w/ (2) 0.5" dia. holes GF 15/26
Speed
Max amps
[A]
P Max
[Watts]
Start amps
[A]
All 3-phase, 460V and 575V pumps are 2-speed only.
Canada only.
208-230V 460V 575V 208-230V 460V 575V
3 1.10 0.55 0.44 280 5.00 2.80 2.20
2 0.72 0.36 0.29 235 3.93 1.96 1.60
10.58▲▲195 3.16 ▲▲
UPS 32-80/2
3 ph, 208-230 V, 460 V, 575 V
, 60 Hz