Brochure

Table Of Contents
Curve charts and technical data
UP, UPS Series 200
9
25
9. Curve charts and technical data
UPS 32-40/4, 1 ph, 115 V, 230 V, 60 Hz
Note: ETA is calculated as wire-to-water efficiency.
Dimensions
Product numbers Connections
Electrical data
TM00 9510 0697
Flow range: 9 - 52 gpm
Head range: 1 - 11 ft
Motor: 4-pole 0.33 Hp
Max. liquid temp (Open): +140 °F
Max. liquid temp.: +248 °F
Min. liquid temp.: +32 °F
Max. system pressure: 145 psi
Net wt: 35.9 lbs (16.3 kg)
Gross wt.: 43.4 lbs (19.7 kg)
Shipping volume: 1.70 ft
3
(0.048 m
3
)
Net wt. bronze: 39.2 lbs (17.8 kg)
Gross wt. bronze: 46.7 lbs (21.2 kg)
Shipping volume bronze: 1.70 ft
3
(0.048 m
3
)
0 10 20 30 40 50 60 Q [US GPM]
0
2
4
6
8
10
12
H [ft]
0
1
2
3
H [m]
0 2 4 6 8 10 12
Q [m³/h]
1
2
3
0 10 20 30 40 50 60 Q [US GPM]
0
50
100
150
P1 [W]
0
20
40
60
Eta [%]
0.0
0.1
0.2
P1 [hp]
3
2
1
Eta
TM02 0729 5100
NPT 1/4
M
D5
D3
D2
D1
B7
B4
B5
L1
L3
D4
D6
D7
B2
B1
H2
H1
H3
Model L1L3B1B2B4B5B7H1H2H3D1D2D3D4D5D6D7 M
UPS 32-40/4
[in] 11.00 5.50 5.31 5.56 3.00 3.00 3.19 2.69 9.50 12.24 1.44 2.56 3.14 4.63 0.50 1.81 2.25
[mm] 279 140 135 141 76 76 81 68 241 311 37 65 80 117 13 46 57 M12
Model type
Product number
Voltage
[V]
Cast Iron Bronze
UPS 32-40/4 (1 ph)
96402694 96402699
115
96402695 96402700
230
Flange size Flange type
1.25" non ANSI 2 bolt w/ (2) 0.5" dia. holes GF 15/26
Speed
Max amps
[A]
P Max
[Watts]
Start amps
[A]
115V 230V 115V 230V
3 1.08 0.54 120 2.10 1.00
2 1.04 0.52 100 2.02 0.96
1 0.95 0.47 85 1.85 0.87
UPS 32-40/4
1 ph, 115 V, 230 V, 60 Hz