Brochure
Table Of Contents
- 1. Product introduction
- 2. Product overview
- 3. Product range
- 4. Cross-reference guide
- 5. Construction
- 6. Operating conditions
- 7. Functions
- 8. Technical data
- 9. Curve charts and technical data
- UPS 32-40/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 32-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 32-80/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 32-80/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 32-160/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 32-160/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-40/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 40-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-80/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 40-80/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-80/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 40-80/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-160/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 40-160/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-240/2, 1 ph, 230 V, 60 Hz
- UPS 40-240/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-40/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 50-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-80/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 50-80/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-80/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 50-80/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-160/2, 1 ph, 230 V, 60 Hz
- UPS 50-160/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-240/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 53-55/57, 1 ph, 115 V, 230 V, 60 Hz
- UPS 53-55/57, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 75-69/2, 1 ph, 230 V, 60 Hz
- UPS 75-69/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 80-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 80-80/4, 3 ph, 208-230 V, 60 Hz
- UPS 80-160/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 100-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UP 43-70, 1 ph, 115 V / 230 V, 60 Hz
- UP 43/110, 1 ph, 115 V / 230 V, 60 Hz
- UP 53-45, 1 ph, 115 V / 230 V, 60 Hz
- UP 53-46, 1 ph, 115 V / 230 V, 60 Hz
- 10. Accessories and spare parts
- 11. Further documentation
Technical data
UP, UPS Series 200
8
24
Technical data, UP
Curve conditions
The guidelines listed below, apply to the performance
curves in section 9. Curve charts and technical data:
1. Because of the danger of overheating, the pumps
must not be used at a flow below 0.1 x Q at best
efficiency point.
2. The bold parts of the curves show the
recommended performance range.
3. Test liquid: Airless water.
4. The curves apply to a liquid temperature
of 68 °F (20 ºC).
All curves show average values and should not be
used as guarantee curves. If a stated minimum
performance is required, individual measurements
must be made.
UPS 100-40/4
96402934 96402937
1.00 3
208-230
3 2.50 570 10.80
2 1.38 435 5.96
1 1.24 390 5.36
96402935 96402938
460
3 1.24 570 5.40
2 0.70 435 3.05
▲▲▲▲
96402936 96401961
575
3 1.00 570 4.32
2 0.55 435 2.44
▲▲▲▲
▲
All 3-phase, 460V and 575V pumps are 2-speed only.
Canada only
Model
Cast iron
product
number
Bronze
product num-
ber
Max. Hp
Speed 3
Ph Voltage Speed
I-MAX.
[Amps]
P-MAX.
[Watts]
Istart
[Amps]
Pump type
Cast iron
product number
Bronze
product number
Hp Ph Voltage I-MAX [Amps] P-MAX [Watts]
UP 43-70
96439644
— 0.50 1 115/230 3.4/1.8 400
UP 43-110
96439643
— 0.75 1 115/230 4.9/2.5 570
UP 53-45
96633576 96633578
0.50 1 115/230 3.5/1.9 360
UP 53-46
96633591 96633592
0.75 1 115/230 3.9/2.1 420