UPS 50-80/2 F Submittal

Company name:
Created by:
Phone:
Date: 2/22/2016
Printed from Grundfos Product Center [2015.09.024]
Position Count Description
Installation:
Range of ambient temperature: 32 .. 104 °F
Maximum operating pressure: 145 psi
Flange standard: USA
Type of connection: F
Pipe connection: GF 50
Pressure stage: 145 psi
Port-to-port length: 11 1/2 in
Electrical data:
Number of poles: 2
Power input in speed 2: 440 W
Max. power input: 610 W
Main frequency: 60 Hz
Rated voltage: 3 x 460 V
Current in speed 2: 0.6 A
Current in speed 3: 0.96 A
Cos phi in speed 2: 0,92
Cos phi: 0,8
Enclosure class (IEC 34-5): X4D
Insulation class (IEC 85): F
Winding resistance: 53.5 - 70.0 ohm
Others:
Net weight: 48.7 lb
Gross weight: 53.4 lb
Shipping volume: 2.08 ft³
4/9