Brochure
Table Of Contents
- 1. Product introduction
- 2. Product overview
- 3. Product range
- 4. Cross-reference guide
- 5. Construction
- 6. Operating conditions
- 7. Functions
- 8. Technical data
- 9. Curve charts and technical data
- UPS 32-40/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 32-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 32-80/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 32-80/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 32-160/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 32-160/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-40/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 40-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-80/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 40-80/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-80/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 40-80/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-160/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 40-160/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 40-240/2, 1 ph, 230 V, 60 Hz
- UPS 40-240/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-40/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 50-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-80/4, 1 ph, 115 V, 230 V, 60 Hz
- UPS 50-80/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-80/2, 1 ph, 115 V, 230 V, 60 Hz
- UPS 50-80/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-160/2, 1 ph, 230 V, 60 Hz
- UPS 50-160/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 50-240/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 53-55/57, 1 ph, 115 V, 230 V, 60 Hz
- UPS 53-55/57, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 75-69/2, 1 ph, 230 V, 60 Hz
- UPS 75-69/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 80-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 80-80/4, 3 ph, 208-230 V, 60 Hz
- UPS 80-160/2, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UPS 100-40/4, 3 ph, 208-230 V, 460 V, 575 V«, 60 Hz
- UP 43-70, 1 ph, 115 V / 230 V, 60 Hz
- UP 43/110, 1 ph, 115 V / 230 V, 60 Hz
- UP 53-45, 1 ph, 115 V / 230 V, 60 Hz
- UP 53-46, 1 ph, 115 V / 230 V, 60 Hz
- 10. Accessories and spare parts
- 11. Further documentation
Cross-reference guide
UP, UPS Series 200
4
8
4. Cross-reference guide
Armstrong, B&G and TACO to Grundfos
Bronze version to be used in open systems.
Replacement model requires piping and/or flange modification.
Disclaimer: This cross-reference is a guide only. Use individual technical data sheets for correct comparison.
Manufacturer Model
Port-to-port
length
[in]
Flange size
[in]
Grundfos model
Port-to-port
length
[in]
Flange size
[in]
Armstrong
ARMflo E21 8.50 1.50 UP43-110F 8.50 1.50
ARMflo E23 8.50 1.50 UP43-110F 8.50 1.50
S 45 10.00 2.50, 3 UP53-45F
9.88 2.00, 2.50, 3.00
S 46 10.00 2.50, 3 UP53-46F
9.88 2.00, 2.50, 3.00
S 55 12.00 3.00 UPS53-55/57F
11.88 2.00, 2.50, 3.00
S 57 12.00 3.00 UPS53-55/57F
11.88 2.00, 2.50, 3.00
S 69 14.25 3.00 UPS75-69F
14.00 2.00, 2.50, 3.00
H51 11.50 1.00 UPS32-80/2
11.00 0.75 to 1.50
H52 11.50 1.00 UPS32-80
11.00 0.75 to 1.50
H53 11.50 1.50 UPS40-160/2
11.50 1.50
H54 11.50 2.00 UPS50-80/2
11.50 2.00
H63 13.50 1.50 UPS32-160/2
13.50 1.50
H64 13.50 1.50 UPS32-160/2
13.50 1.50
H65 13.50 1.50 UPS40-240/2
13.50 1.50
H66 14.00 2.00 UPS50-160/2
14.00 2.00
H67 14.00 2.00 UPS50-160/2
14.00 2.00
H68 14.00 2.00 UPS50-240/2
14.00 2.00
1050 1B (0.25 Hp) 11.50 1.00 UPS32-80/2
11.00 0.75 to 1.50
1050 1-1/4B (0.25 Hp) 11.50 1.25 UPS32-80/2
11.00 0.75 to 1.50
1050 1-1/2B (0.25 Hp) 11.50 1.50 UPS32-80/2
11.00 0.75 to 1.50
1050 2B (0.33 Hp) 11.50 2.00 UPS50-80/4
11.50 2.00
1050 2B (0.50 Hp) 11.50 2.00 UPS50-80/4
11.50 2.00
1050 2B (0.75 Hp) 11.50 2.00 UPS50-80/4
11.50 2.00
1060 1-1/2 D (0.50 Hp) 13.50 1.50 UPS32-160/2
13.50 1.50
1060 1-1/2 D (0.75 Hp) 13.50 1.50 UPS32-160/2
13.50 1.50
1060 1-1/2 D (1.50 Hp) 13.50 1.50 UPS40-240/2
13.50 1.50
1060 2D (0.75 Hp) 14.00 2.00 UPS50-160/2
14.00 2.00
1060 2D (1.00 Hp) 14.00 2.00 UPS50-160/2
14.00 2.00
1060 2D (1.50 Hp) 14.00 2.00 UPS50-160/2
14.00 2.00
1060 2D (2.00 Hp) 14.00 2.00 UPS50-240/2
14.00 2.00
TACO
120 11.00 2.00 UPS32-40/4
11.00 0.75 to 1.50
131 13.63 3.00 UP53-45F
10.00 2.00, 2.50, 3.00
133 13.63 3.00 UPS53-55/57
11.88 2.00, 2.50, 3.00
1600 10.25 1.50 UPS32-80/2
11.00 1.50
1610 10.25 1.50 UPS32-80/2
11.00 1.50
1612 13.50 1.50 UPS32-160/2
13.50 1.50
1614 13.50 1.50 UPS32-160/2
13.50 1.50
1616 14.50 2.00 UPS40-240/2
13.50 1.50
1630 13.50 2.00 UPS50-80/4
11.50 2.00
1632 13.50 2.00 UPS50-160/2
14.00 2.00
1634 13.50 2.00 UPS50-160/2
14.00 2.00
1636 16.50 2.00 UPS50-240/2
14.00 2.00
1638 16.50 2.00 UPS50-240/2
14.00 2.00